Specifications
HARD-WIRED ZONES
Zones 1-6 The VISTA-10 supports 6 hard-wired zones, which are connected as zones 1-6.
(Basic Control’s Zones)
These zones must be EOLR supervised, and can use N.O. and/or N.C. sensors.
Zone Response Type
Any zone response can be assigned to devices on
these zones except Supervised Fire (09), which
can be assigned only to zone 5 (see below).
Response Time
300-500 msec. Zone 3 is optionally programmable
for fast (1O-15msec) response.
Max. Zone Resistance
300 ohms, excluding EOLR.
EOLR Supervised
. Supports both open circuit and closed circuit
devices.
● Connect open circuit devices in parallel across
the loop. The 1,000 ohm EOLR must be
connected across the loop wires at the last
device.
Important If the EOLR is not at the end of the
loop, the zone is not properly supervised. The
system may not respond to an open circuit within
the zone.
. Connect closed circuit devices in series with the
HI side of the loop.
EOLR Fire Zone 5
● Of the 6 hard-wired zones, only zone 5 can be
used for fire.
● Suppotts as many 4-wire smoke detectors as can
be powered.
. The zone must be configured for EOLR
supervision.
● The detectors must be wired in parallel, with the
EOLR at the last detector for full supervision.
● To supervise power, a supervisory module (e.g.,
System Sensor A77-716B EOL Relay Module) is
required.
–7-