Specifications
(continued) OUTPUT RELAY EXAMPLES TABLE
RELAY
ACTION DESIRED
ACTION
START
STOP
A EV ZL ZT ZL ZT
Close relay
at start of entry time and reset with key entry of 2 0 0 32 0 34
security code + # + 7.
●
‘Can be used to turn on a /ight when entry door is opened.
Close relay after any burglary alarm and reset with key entry 2
0 0 33 0
35
of security code + # + 8.*
*Can be used to turn on iighfs in the event of a burgla~
alarm,.. (NOTE: Response types 06, 08, and 09 will not
activate relay).
Zones in zone list (x) close relay on alarms and reset with
2
1
x
00 0 34
key entry of security code+ # + 7. (Possible use with strobe
light)
Zones in zone list (x) pulse relay on alarms and reset with 3
1 x
00 0
34
key entry of security code+ # + 7.
A system low battery detection causes relay to close for 2 1
0 0
42 0 00
seconds.*
An AC loss detection causes relay to close for 2 seconds.* 1 0 0 41 0 00
●The relay will not reset on restoral of low battery orAC
power. For this reason, using “close for 2 seconds” in
A(action) is recommended.
Bypassing a zone will cause relay to close for 2 seconds.
1
0 0 40 0
00
Bypassing a zone causes relay to close and will reset with a 2 0 0
40 0 22
disarm sequence (code + off.)
Any FIRE alarm causes relay to pulse on and off and will
3 0 0 39 0
22
reset with an entry of a disarm sequence (code + off.)
An alarm or trouble condition on any FIRE zone causes
1 0 0 09 0 09
relay to close and will reset when condition clears.
-45-