Specifications

OUTPUT RELAY EXAMPLES TABLE
RELAY
ACTION DESIRED
START
STOP
ACTION
A
EV ZL ZT ZL ZT
Zones in zone list (x) close relay for 2 seconds on alarms.
1
1
x
00 0 00
Zones in zone list (x) close relay for 2 seconds on troubles.
1
3 x 00 0 00
Zones in zone list (x) close relay for 2 seconds on faults*.
1 2
x
00
0
00
‘Will activate relay for any zone type plus panics on 5801
whether control is armed or disarmed. (Console panics will
not activate a relay with the configurations above.)
Zones
in zone list (x) close relay on alarms and reset at bell
2
1 x
00 0 36
timeout or when disarmed.
Zones in zone list (x) pulse relay on alarms and reset at bell
3
timeout or when disarmed.
1
x
00
0
36
Zones in zone list (x) close relay on alarms and reset when
2
1
x
00 x 00
zone is restored.*
Zones in zone list (x) pulse relay on alarms and reset when
3
1 x 00 x 00
zone is restored.*
*Console panics or zone type 23 will not activate a relay with
these configurations. The relay can also be activated by
troubles or faults by changing the EV (event) accordingly.
Zones in zone list (x) close relay on alarms and reset when
2
1
x 00 0 22
disarmed. (Latching relay for strobes.)*
Zones in zone list (x) pulse a relay on alarms and reset when 3
1
x
00
0
22
disarmed.*
“Relay wi(l activate for burglary, fire, and panic a/arms if
programmed into zone list.
Close relay after any burglary alarm and reset when
2 0
0 33
0 22
disarmed.*
Close relay after any burglary alarm and reset at bell timeout 2
0
0
33
0 36
or when disarmed. *
*Response types 06,08, and 09 will not activate relay. /f
PULSE relay is desired, enter a 3 in A (action).
Close relay when ARMED-AWAY, reset when DISARMED.* 2
0
0 21 0 22
Close relay when ARMED-STAY, reset when DISARMED.* 2
0 0 20 0 22
“If PULSED relay is desired, enter a 3 in A (action).
Close relay for 2 seconds at end of exit delay time after 1
0
0 31 0 00
system is armed (Confirmation ding).
Pulse relay at start of entry time and reset when system is
3
0
0 32 0 22
disarmed (entry warning).
Close relay for 2 seconds during chime. (Chime mode must 1
0
0 38 0 00
be turned on at control.)
–44–