1. Physical: 12-1/2’’ Wx14-l/2” Hx3D (318mmx368mmx76mm)
2. Electrical:
VOLTAGE INPUT: 16.5VAC from plug-in 25VA transformer, Ademco No.
1321/TF2 (in U.S.A.)
Nofe: For Canadian installations, a No. 1321 CN transformer must be used.
RECHARGEABLE BACK-UP BAITERY: 12VDC, 4AH (Gel type), Ademco No. 467.
Charging Voltage: 13.8VDC.
/Vote; For California fire alarm installations, see the CSFM battery back-up
requirements on page 49.
ALARM SOUNDER: f2V, 2.0Amp output can drive 12V BELLS or can drive one
or two 702 (series connected) self-contained 20-watt sirens. Do not
connect two 702s in parallel.
AUXILIARY POWER OUTPUT: 12VDC, 500mA max. Interrupts for smoke
detector reset.
Note: For UL installations, Alarm Sounder plus Auxiliary Power currents should
not exceed 600mA total.
STANDBY TIME: 5 HRS with Auxiliary load of 500mA (using 4AH battety).To
determine total standby battery load, add 100mA to total Aux. power output
and remote console currents.
FUSE:
Battery (3A) No. 90-12
3. Communication:
FORMATS SUPPORTED:
Ademco Express,
10 characterskec, DTMF (TouchTone) Data Tones, 1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Contact ID Reporting,
10 characters/see., DTMF (TouchTone) Data Tones, 1400/2300Hz ACK,
1400Hz KISSOFF.
Ademco Low Speed, 10 pulses/see, 1900Hz Data Tone,
1400Hz ACWKISSOFF.
Radionics/SESCOA, 20 pulses/sec,l 800Hz Data Tone,
2300Hz ACWKISSOFF.
Can report O-9, B-F
Line Seize: Double Pole
FCC Registration No.: AC 398 U-681 92-AL-E
Ringer Equivalence: 0.7B
1. Physical: 5-5/8”Wx4-11/16” H x 7/8” D (143mm x 119mm x 22mm)
2. Electrical: Voltage Input: 12VDC,
Current Drain: 20mA
3. Interface Wiring:
To control panel’s console connection points.
RED: 12VDC input (+) aux pwr
GREEN: Data Out to Control
YELLOW: Data In from Control
BLACK: Ground
1. Physical: 8-2/5” W x 4-3/4” H x 1-1/10” D (213mm x 121mm x 28mm)
2. Electrical: Voltage Input 12VDC,
Current Drain: 60mA (4137AD)
90mA (5137AD)
3. Interface Wiring:
RED:
BLUE:
GREEN:
YELLOW:
BLACK:
12VDC input (+) aux pwr
18VDC input from optional No 1350 or 1360 Power Pack
(not usable for UL installations)
Data Out to Control
Data In from Control
Ground and (-) connection from
optional No. 1350 or 1360 Power Pack