Specifications

Example of
Let us light an indicator when any one of 3 specific zones are
Output Relay
faulted or when any 24 hour aux. zone is disturbed. We want to
Programming
turn off the indicator manually without affecting the arming status
of the system.
FOR OTHER EXAMPLES
In field *8O we choose Output Relay 01 and program the Action (A) to be “2”
SEE THE TABLE
(Close and stay closed). The Event we are looking for to start the relay action is a
ON PAGE 44
fault, so we will program “2” in (EV). We will use Zone List 1 for the 3 specific
zones, so will program “1” in (ZL), (and will program these 3 zones in field
81’s
Zone List
1).
The second condition for turning on the indicator is triggering a 24 hour aux. zone
(Zone Type 08), so we will program (ZT) as “08”.
To stop relay action and turn off the indicator, we do not want to use a restore of
any zone, so we will program a “O” for the “Restore of’ Zone List (ZL). To choose a
manual entry of User Code+ [#] + ~] to turn it off, we will program (ZT) as “34”.
If no other relay is to be programmed we go to field
81 and program the 3 specific
zones in Zone List 1.
’81
ZONE LISTS FOR OUTPUT RELAYS
Zone List Displays
Applicable only if field *25 is programmed for a 4204... otherwise skip this
field.
-
Upon entering field *81, this screen will appear. Enter the Zone List Number 01,
02, or 03 to program (or 00 to end these entries). Press the [~] key to advance.
In the following displays, zone list 03 has been selected for programming.
J
Zone Listselected.
mootoacfvance.
Enter each zone number to add to the zone list by first entering the zone number,
then the [x] key (ex., 01X, 02X, 03X). After all desired zones are entered, enter
FEzl
To delete the zone list, enter 1 (Yes). All zones in the zone list will be deleted
automatically and programming will return to the first screen.
O= NO 1 = Yes O To save the zone
list, enter O (No) to advance.
rescreen
To save the entire zone list, enter O (No) and programming will return to the first
0 =‘0 1 = ‘es 0 To delete a zone or zones in a zone list enter 1 (Yes) to advance.
m
Enter each zone to be deleted from the list, followed by the [x] key. After all
zones to be deleted are entered, enter 00 to return to the first screen so that
00 another list can be programmed, if desired. .
Notes:
Any list may include any or all of the system’s zone numbers.
A zone list can be assigned to more than one output relay.
*82
83
92
DOWNLOAD
*94
INFORMATION
(*94, *95)
*95
If you only want to re~iew what has been programmed previously,
enter [#][8][1 ]. The review can be advanced by using the [#] key.
When finished, enter [0][0] to quit. No programmed values can be
disturbed in this mode.
CUSTOM ALPHA EDITING (Also entered from field
56)
~ See ALPHA DESCRIPTION ENTRIES section on page 29; 1
ADD/DELETE 5800 RF INPUT IDs (Serial Nos & Sensor Pts)
See procedure in last paragraph of field
56.
MAXIMUM NUMBER OF REPORTS PER ARMED PERIOD
Enter: Ofor a maximum of 10 total alarm plus alarm restore reports,
or: 1 for an unlimited number (must be se/ected for U/- insta//ations).
DOWNLOAD PHONE NUMBER
Enter up to 12 digits, O-9, #+11 for ‘x’, #+12 for ‘#’, #+13 for a pause. Do
not fill unused spaces. If fewer than 12 digits entered, end field by
entering X (and press next field number). To clear field, press X94X.
RING DETECTION COUNT FOR DOWNLOADING
Enter number of rings before control picks up phone line (or O or 15).
O= disable station initiated download
1-14= #of rings
15=
answering machine defeat