Specifications
Ex!Ea
Re\aybeingprogrammed.
Es_3
E==7
Upon entering field ●80, this screen will appear. Enter the Relay Number 01, 02,
03, or 04 for a 4204 (or 00 to end these entries). Press the [++]key to advance.
The data is keyed in and entered for this and the following screens by pressing [*]. To
back up to checkan entry, p
reea [#] for each position. Press [~] to go forward again.
This screen displays a summary of the current relay START programming (for this
example, relay 02 has been selected). Press the [~] key to advance.
This screen displays a summary of the current relay STOP programming. Press
the [~] key to advance.
Action (A~ Enter the desired relay action. Press the [~] key to advance.
o = Not Used
2 = Close and Stay Closed
1
= Close for 2 seconds 3 =
Continual Pulses (1 see) On and Off
Event (EV): Enter the event to START the relay. Press the [+$] key to advance.
o
= Not used 2
= Fault
1 = Alarm 3
= Trouble
Zone List (ZL): If a zone list will be used to START the relay action, enter the
zone list number (to be programmed in field
●81 ): 1, 2, or 3. If not used, enter O.
Press the [~] key to advance.
Zone Type/System Operation (zT): If a zone type or system operation will
be used to START the relay action, enter the appropriate two digit code. If not,
enter 00. Press the [~] key to advance.
CHOICES FOR ZONE TYPES
00=
Not Used
01 = Entry/Exit
05= Trouble Day/Alarm Night
08= 24 HrAux
03= Perimeter
06= 24 Hr Silent
09= Fire
04= Interior Follower
07= 24 Hr Audible
10= Interior w/Delay
CHOICES FOR SYSTEM OPERATION
20=
Arming-Stay
33= Any Burglaty Alarm
38= Chime
21 = Arming-Away
34= Code+ #+7 Key Entry
39= Any Fire Alarm
22= Disarming (Code + OFF) 35= Code+ # + 8 Key Entry
40= Bypassing
31 = End of Exit Time
36= At Bell Timeout**
41 = AC Power Failure
32= Start of Entry Time
37= 2 times Bell Timeout**
42= System Battery Low
**Or at Disarming, whichever occurs earlier.
“Restore of” Zone List (ZL): If a zone list will be used to STOP the relay ac-
tion, enter the zone list number (to be programmed in field ‘81): 1, 2, or 3. If not
used, enter O. Press the [~] key to advance.
Zone Type/System Operation (ZT):
If a zone type or system operation will
be used to STOP the relay action, enter the appropriate two digit code (see the
“~ choices listed above). If not, enter 00. Press the [++]key to advance.
This screen again displays a summary of the current relay START programming.
Press the [++]key to advance.
This screen again displays a summary of the current relay STOP programming.
Press the [~] key to return again to the first screen so that the next relay number
to be programmed can be entered, or enter [0][0] to end relay programming.
/Vote: Previous/y entered data can be reviewed by pressing [#] [8] [0]. After the’
relay number is chosen, press [#] to go to the next screens. This is a re-
view mode onty, and data cannot be changed.
-25-