Specifications
TO PROGRAM SYSTEM
With a 3+1 or 4+1 Standard Format: Enter a code in the
first digit box: 1-9, 0, B, C,
STATUS & RESTORE
D, E, or F. Enter “#+1O for O,
“#+11” for B, “#+12” for C, “#+13” for D, “#+14” for E, “#+15°
REPORT CODES
for F.
(“60 -’75)
A “O”(not
“#+10”) in the first digit box will disable a report.
A “O”(not “#+1O“)in the second digit box (if any) will result in automatic advance to the
next field when programming.
With
an Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits)
for 1-9, 0, or B-F, as described above.
A “O (not “#+1O) in the second box will eliminate the expanded message for that report,
A “O”(not “#+1O) in both boxes will disable the report.
With Ademco Contact ID Reporting: Enter any digit (other than “O) in the first box,
to enable zone to report This is an “enabling” code only and is disregarded in the actual
reporting to the central office. Entries in the second boxes will be ignored.
A “O”(not “#+10) in the first box will disable the report.
n.- F. .-—-,-.-— —--—--———.——,———
CJee cxarryxes on programming Term.
SYSTEM STATUS *6O
REPORT CODES
*61
(*60-*68) *6*
●63
*64
●65
●66
●67
*68
RESTORE *69
REPORT CODES
(*69-*75)
*7O
*71
*72
*73
*74
●75
TROUBLE REPORT CODE (See box above.)
BYPASS REPORT CODE (See box above.)
AC LOSS REPORT CODE (See box above.)
LOW BAT REPORT CODE (See box above.)
TEST REPORT CODE (See box above.)
OPEN/EXIT ALARM REPORT CODE, 1st DIGITS
Open Report Code
: To enable, enter a code (or O to disable) in the
left-hand box (see box above ‘60).
For exoanded or 4+2 re~ort in~ 2nd digit = User #.
Exit Alarm Report Code: To enable, enter a code (or O to disable) in
the right-hand box (see box above ‘60). If enabled:
ANY ALARM FROM AN EXIT OR INTERIOR ZONE OCCURRING WITHIN TWO
MINUTES AFTER THE END OF THE EXIT
DELAY will send a special message
indicating exit alarm to the central station, and a zone indication and “Exit Alarm”
or “EN is displayed on the console.
IF AN EXIT OR INTERIOR ZONE CONTAINS A FAULT AS THE EXIT DELAY
ENDS, the local bell and console sound continuously.
a) V the subscriber then disarms the system befo;e the ensuing ENTRY de/ay
ends, no message is transmitted to the central station, but a zone indication
and “Canceled Alarm” or “CA is displayed on the console.
b) //the system is not disarmed before that entry de/ay ends,
a special message
indicating Exit Alarm is sent to the central station and a zone indication and
“Exit Alarm” or “EN is displayed on the console.
For ex~anded or 4+2 re~ortin~ a 2nd digit is sent, and is the same as the
2nd digit of the zone alarm report code programmed in field *56.
For Contact
ID reportina~
Event code 374 and the zone number is sent.
There is no restore message for Exit Alarm report.
AWAY/STAY CLOSE RPT CODE, 1st DIGITS (See box above.)
To enable, enter a code (or Oto disable) in either or both boxes
For ex~anded or 4+2 reporting, 2nd digit for each= User #.
RF XMTR. LOW BATTERY REPORT CODE (See box above.)
CANCEL REPORT CODE (See box above.)
GROUP RESTORES FOR TROUBLE, RF LOW BAT, BYPASS
Enter: Ofor no (report for each restore),
oc 1 for yes (report after all zones restored).
Note:
“1” not applicable to Contact ID reporting.
ALARM RESTORE REPORT CODE, 1ST DIGIT
For exuanded or 4+2 reDortinm a 2nd digit is sent, and is the same as the
2nd digit of the zone alarm report code programmed in field *56.
TROUBLE RESTORE REPORT CODE (See box above.)
BYPASS RESTORE REPORT CODE (See box above.)
AC RESTORE REPORT CODE (See box above.)
LOW BAT RESTORE REPORT CODE (See box above.)
RF XMTR. LOW BATTERY RESTORE CODE (See box above.)
-23-