Specifications

Eiiiml
24-hour Silent Alarm
IEiiiml
24-hour Audible Alarm
24-hour
Auxiiiary Aiarm
EiiEmil
Supervised Fire
Eiiiiml
interior w/Deiay
Eiiimil
Arm-Stay
m
Arm-Away
Eiiiiz@
Disarm
Eia31
No Aiarm Response
This zone type sends a report to the Central Station but provides no console
display or sounding. This zone tvoe is usua Ilv assianed to a Tone contamw
. .
Emeraencv butto ,n
This zone type sends a report to the Central Station, and provides a rapid
beeping sound at the console, and an audible external alarm. This zone tyDe
is
usua
Ilv assianed to a zone that has an Emeraencv butto
n.
This zone type sends a report to Central Station and provides a rapid beeping
sound at the console. (No beii output is provided). This zone tvpe
is usu-
allv assianed to a zone containing
a button for use in Dersonal emergencies,
or to
a zone containing monitoring devices such as water or temperature sensors, etc.
This zone type provides a fire alarm on short circuit and a trouble condition on
open circuit. The bell output will pulse when this zone type is faulted. This zone
type is always active and cannot be bypassed. This zone
tvD
e
can be ass ianed tQ
control
D
anel wired zone 5
or to certain wireless zones.
This zone type gives entry delay (using the programmed entry time), if tripped
when the panel is armed in the Away mode, regardless of whether or not an en-
try/exit delay zone was tripped first. This zone type is also active during Maximum
mode, but no entry delay is provided (an alarm occurs immediately if the zone is
tripped). Exit delay is present for any arming mode. This zone type is
bypassed automatically when the panel is armed Stay or instant .
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in arming the System in the STAY
mode when the zone is activated.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in arming the system in the
AWAY mode when the zone is activated.
This is a special purpose zone type used with 5800 series wireless pushbutton or
contact closure or opening, and which will result in disarming the system when the
zone is activated.
This zone type can be used on a zone when an output relay action is desired, but
with no accompanying alarm (ex. lobby door access).
By using a 4281/5881 RF Receiver and the appropriate 5700/5800 series transmitters,
all of the above zone types are available for the wireless portion of the system.
When the display shows the zone type you want, press [~] to advance
EziEJ :pre55[*1toad
Report Code (RC): The report code consists of 2 hexadecimal digits,
each in turn consisting of 2 numerical digits. For example, for a report
code of “3C”, enter [0][3] for “3” and [1][2] for “C”. Enter the numbers
...
Input Device (In): For the hard wired zones of the ViSTA-l O (HW),
and the zones for a 5700 system’s transmitters (RF), the Input Device
types are automatically assigned (Panic, Duress, and Tamper inputs are
not applicable).
m
For a 5800 system’s transmitters, “RF” is initially displayed, but should be
changed to “UR” (Unsupervised RF, enter 4) for units that can be carried
off-premises (e.g., No. 5801 ), or to “BR” (Button type RF, enter 5) for
small transmitters that cannot be supervised (e.g., Nos. 5802, 5802CP,
5803). Check the instructions that come with the transmitter for the
proper input. When all is okay, press [~] to advance to...