Specifications

*52
ZONE ASSIGNMENT/
*56
ALARM REPORT
CODES, etc.
(*56)
Enter Zn Num.
(OO=Quit) 20
Zone 20 entered~
Zone Type
T
ZONE 3 RESPONSE TIME TO OPEN
O = 400ms nominal
1 = 10ms nominal
ZONE ASSIGNMENT/ALARM REPORT CODES
(and RF Input ID Learning for 5800 System)
REFER TO THE ZONE ASSIGNMENT TABLE FOR THIS FIELD
ON THE CENTERFOLD PROGRAMMING FORM
This field is used to program zone numbers, zone types, alarm and report
codes, and to identify the type of loop input device. This field can also be
used for “learning” 5800 series transmitter ID codes and for entering al-
pha descriptors for zones.
Zone Number (Znk UDon enterina field *56, enter the zone number
that you wish to program” (or [0][0] to ~eave zone” programming).
Press [+$]. A summary display will come up, showing the status
zone’s program.
of that
If it is programmed satisfactorily, press [#] to back up one step and enter
another zone number, if desired.
If the zone is not programmed, or you want to change it, press [++]. A
prompt for Zone Type will appear.
Zone Type (ZT):
Each zone must be assigned to a zone type, which
defines the way in which the system responds to faults in that zone.
Enter the zone type code (or change it, if necessary). Zone types are
defined below.
ZONE RESPONSE TYPE DEFINITIONS
Eiiiim
Zone Not Used
m
Entry/ExltBurglary
Eiiiiml
Perimeter Burglary
m
Interior, Follower
IzYeQsl
Trouble by Day/
Alarm by Night
e 02
is not used m ths svstem,
i
Program a zone with this zone type if the zone is not used.
This zone type provides entry delay whenever the zone is faulted if the control is
armed in the Away or Stay modes. When the panel is armed in the Instant or
Maximum modes, no entry delay is provided, Exit delay begins whenever the
control is armed, regardless of the arming mode selected. These delays are
programmable. This zone tvpe s usually ass aned to se
i i
nsors or contacts or_I
doors th ouar h which primarv entrv and exit will take placa
This zone type gives an instant alarm if the zone is faulted when the panel is
armed in the Away, Stay, Instant or Maximum modes. This zone tv~e M US*
@aned to all sensors or contacts on exter o doors air nd windows,
This zone type is active when the panel is armed in the Away or Maximum modes.
Entry delay (using the programmed entry time) results if the panel is armed in the
Away mode and the entry/exit zone is faulted first. Otherwise this zone type gives
an instant alarm. Exitdelay is present for any arming mode. ~S
i
u II
in oazn covrin
~
h as a fever, I
r hal w
t
ro~ fter faultina th
ntrv/exit zon
re
ach the c
onsole to disarm the svstern. Since this zone type is designed to pro-
vide an instant alarm if the entry/exit zone is not violated first, it will protect an area
in the event an intruder hides on the premises prior to the system being armed, or
gains access to the premises through an unprotected area. This zone type is
bypassed automatically when the panel is armed Stay or Instant.
This zone type will give an instant alarm if faulted when armed in the Away, Stay,
Instant or Maximum (night) modes.
During the disarmed state (day), the system
will provide a latched trouble sounding from the console (and a central station
report, if desired). This zone tvDe
is usuallv assianed to a zone which contains a
f il- r tect
~ verin
~This zone type can _
also be used on a sensor or contact in an area where immediate notification of an
entry is desired.
–20-