PROGRAMMING DATA FIELDS
I THE CENTERFOLD PROGRAMMiNGFORM
CAN BE USED TO RECORD THE DATA FOR THIS INSTALLATION
[
SYSTEM SETUP *2O
(“20-’27)
*21
22
*23
*24
25
*26
*27
ZONE SOUNDS AND
28
TIMING
(*28-*39)
29
*3O
38
’39
MASTER CODE
Enter 4digits,0-9 {entry ofa114 ismandatory).
Use of a “9” in the last position inhibits the duress code feature.
QUICK ARM ENABLE
If enabled, [#] key can be used instead of security code when arming .
Code is always required when disarming.
Enter Ofor disabled or 1 for enabled.
RF SYSTEM TYPE
Select the RF system (receiver) type being used.
O = none; 1 = 5700 (4281); 2 = 5800 (5881)
FORCED BYPASS FUNCTION
All zones that are bypassed by this function will be displayed after the
bypass is initiated.
O= No forced bypass.
1 = Allows quick bypass of all open zones.
RF RECEIVER HOUSE ID CODE
MUST enter for 5700 system’s 4281 type receiver, or 5800 system’s
5827 Wkeless Keypad or 5827BD Bidirectional Console.
Enter 01-31 House ID.
OUTPUT RELAY MODULE
Enter 3 if relay module is being used, or O if not..
O = none; 3 = 4204
VOICE MODULE ACCESS CODE
Supports the 4285 Voice Module on the console lines
(the 4285 has a permanent device address of 4).
To enable, enter two digits, 1st digit: 1-9
2nd digit: ‘~’ (enter #+1 1) or ‘#’ (enter #+12)
To disable, enter O in either position.
OUTPUT TO LONG RANGE RADIO (e.g., No. 7720ECP)
*
Enter Ofor no or 1 for yes.
If yes is selected, any dialer report programmed to report to the PRIMARY
phone number (in field *47) will be sent, as well, via long range radio. All
dialer m long range radio reports will be in Contact ID format (regardless
of the selection made in field *46).
Note: Program the radio for a device address of 3 on the keypad lines.
Full Trouble and Restore messages are sent.
SINGLE ALARM SOUNDING PER ZONE (per armed period)
Affects external sounder only, if yes is selected.
Enter Ofor no or 1 for yes.
FIRE SOUNDER TIMEOUT
O = Fire sounder times out at end of bell timeout period (field ‘30).
1 = Fire sounder continues until silenced manually.
ALARM BELL TIMEOUT
External sounder will shut off after time allotted. Enter 1 digit.
O= No timeout
1 = 4 minutes
2 = 8 minutes
3 = 12 minutes
ENTRY DELAY
System will wait the time allotted before sounding alarm upon entering.
(EXIT delay = Entry delay plus 15 seconds)
O= O see, 1 = 20 see, 2 = 30 see, 3 =45 see, 4 =60 see, 5 =90 sec.
For UL insta//ations, entry de/ay can be no greater that 45 sec.
AUDIBLE EXIT WARNING
When arming AWAY or MAXIMUM, console sounds slow beeps during exit
time, turning into fast beeps during last 5 seconds.
Enter O for no or 1 for yes.
–18–