Specifications

Summary of
Programming
Commands
Special Messages
FUNCTION
PROCEDURE
ENTER PROGRAMMING MODE
INITIALIZE DOWNLOAD ID
AND
SUBSCRIBER ACCT NUMBER
FOR DOWNLOADING
SET ALL PROGRAM FIELDS
TO DEFAULT VALUES
EXIT PROGRAMMING MODE
ADVANCE TO FIELD
PROGRAM FIELD
ERASE FIELDS
READ FIELD
Oc= OPEN CIRCUIT (no corer
EE = ERROR (program entry rr
1. POWER UP, then depress
[~] and [#] both at once, within
50sec of powering up.
OR
2. Initially, key: 4 + 1 + 1 + 1
plus CODE key + O.
IOR
3. If different Master Code is programmed,
key:
MASTER CODE + CODE KEY + O
(if X98 was used to exit previously,
method 1 above must be used to enter
the program mode again)
X96 No data entry required,
loads defaults.
X97 No data entry required.
X98 Inhibits re-entw to Droaramminq
mode via type ~ or’3 efitry metfiod
above.
x99 Allows re-entry to programming
mode via type 2 or 3 entry method.
[~] + Field No. (e.g., 21, 38, 56, etc.)
[~] + Field No., followed by data entries.
Some fields require sequential pressings of
[++]to enter data (e.g., fields 56; 80, 81).
[+$] + Field No. + [+$] (only applies to
fields 40 thru 43 and 94).
[#] + Field No. Data will either be
automatically sequentially displayed or can
be displayed by successively p
ressing [#].
unication between Console and Control).
stake). Re-enter the field number or data).
After powering up, AC, dl (disabled) or System Busy and NOT READY will
be displayed after approximately 4 seconds. This will revert to READY in appx. 1
minute, which allows PIRS, etc. to stabilize. To bypass this delay, press: [#]+ [0].
If E4 or E8 appears, more zones than the expansion units can handle have been
programmed. Correct the programming and then completely de-power and re-
power the control to clear this indication and remove the disable indication.