User manual

40
Vista QPlus H.264 V2.2 (RP03)
Quantum Plus H.264 installation and user manual
Note: Profile 0 cannot be changed. It is always Normal Time Lapse 1 (N1).
To amend the Profiles priority settings click on the Profile list box (not the tick box) e.g. on
AL+M+N1. The following screen will be displayed:
Change the priority listing to suit the schedule requirements. Each priority level can be
selected to be any of the following:
Alarms, Motion, Normal Time Lapse (1 -4), Audio Event, Duration or None.
The record mode at the top of the list is the one that takes priority.
In the example above Alarms will take priority to over all else. So when an alarm input is
triggered the record setting for that input will be used.
If there are no active alarm inputs, then the DVR is looking for cameras with motion in the
scene, when motion is detected then the Motion Record settings will be used.
If there are no active alarm inputs and no motion is detected, the DVR will record using the
Normal Time Lapse 1 settings.
Once the priority settings for all the require profiles have been set, then the timetable can be
programmed for the periods during which each profile is to be used.
To select the hours of the week that each profile is to be used, click in the tick box for that
profile, then click drag on period within the timetable. The Profile number will appear in the
selected boxes, as shown in the next table: