User manual
35
Vista QPlus H.264 V2.2 (RP03)
Quantum Plus H.264 installation and user manual
2-3. Alarm
There are 16 Alarm inputs on the rear of the Quantum these can be used to initiate the Alarm
record mode.
The Alarm recording Quality, FPS and Audio are set up in the same way as Normal
Recording.
SET: This allows the camera that is to be associated to the alarm input to be allocated, along
with up to 3 other cameras which can be sent a telemetry action on receipt of the alarm.
Highlight the Alarm title at the top and select the relevant alarm input number. The camera
selected as the PRIMARY camera, is the one that will show in the Log and on the Calendar
Search menu in the alarm coloured time bar.
Function: can be set to Preset, Tour or Learn
Number: can be set to the relevant Preset, Preset tour or Learn tour number.
Type: can be set to either normally open ( N.O) or normally closed (N.C)
Set: Normal if the alarm is to be used, set to Off if no alarm input is required. Do not use ON,
this will be removed in future firmware versions.