User manual
0150-0201C 55 Vista Columbus System Triplex
q Main Menu → Telemetry → Telemetry Enable
Use this menu to Enable or Disable telemetry of
each camera individually.
Telemetry EnableTelemetry Enable
[CANCEL] [OK]
Camera 01:
Camera 02: Enable
Camera 03: Disable
Camera 04: Enable
:
:
Camera 16: Enable
Disable
q Main Menu → Telemetry → Telemetry
Use this menu to select the telemetry signal type. Select
from either:
Standard: Asynchronous, not synchronized with the
video signal. This is the older style.
Alternate
Standard
Alternate: Synchronous, synchronized with the video signal. This is the newer style.
Standard telemetry may interfere with some on-screen displays. If this happens, try using Alternate
telemetry. Alternate works with Baxall ZR-mini receivers or DAX units. Changing the telemetry type is
a global function, which changes all telemetry outputs.
q Main Menu → Telemetry → Preset Mode
Select either Standard or Enhanced. Enhanced
mode is only available on ZRX-mini receivers
manufactured after February 1996.
Standard
Enhanced
q Main Menu → Telemetry → Preset PGM
Use this menu to Enable or Disable Preset
Programming.
Once the Preset Program is enabled, exit the
menu system and set the camera preset positions
by following the procedures given below.
Disabled
Enabled
The choice of procedure depends on whether Standard or Enhanced mode was selected in the Preset
Mode menu.