0150-0296A 54 Vista Columbus Triplex CDR
3.18 Communications
Use this menu to:
Configure the baud rates and settings for the RS232 ports.
Configure the network address for the RS485 network.
Configure the Ethernet address and networks settings.
q Main Menu Communications RS232
Select the Port you wish to configure and press the ENTER button.
Port 1
Use this menu to:
Enable/Disable POTS and configure the Modem initialisation
string (POTS Setup).
Adjust the Baud rate.
POTS Setup
The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express
56k, and 5686 US Robotics modems in their default conditions. Consult with the modem manual
before attempting to make any changes. It is strongly recommended that the modem initialisation
string only be modified by a qualified technician.
POTS Setup
SEQ key selects character bank
‘1’ key inserts blank character
‘2’ key inserts selected character
@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^
Modem Init String : AT&F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1
POTS : DISABLE
[Default Modem String] [CANCEL] [OK]
1. With the Modem Init String highlighted, press the Enter button to enter the Edit mode. The
character bank will appear in the centre of the menu.
2. Press the Sequence button to select the desired character bank.
3. Rotate the Shuttle to navigate the Modem Init String.
4. Rotate the Jog to select a character from the character bank.
5. Use the Number 2 button or rotate the Shuttle to insert the desired character from the character
bank into the Modem Init String and advance to the next character.
Port 2
Port 1
Baud Rate
POTS Setup
RS485
Ethernet
RS232