Features Q.E.D. programming for quick enrollment of devices. Previous Menu VISTA-20SE 2-PARTITIONED SECURITY SYSTEM PROGRAMMING FORM ® Principal changes between the VISTA-20SE and the former VISTA-20 are indicated by margin lines.
Local programming requires the use of a 2-line Alpha keypad connected to partition 1 keypad terminals on the control. NOTE: For UL installations, the system may be configured as a single partition only. Field Function SYSTEM SETUP (*20–*29) *20 INSTALLER CODE *21 Programmed Values [ ] = Default Value | | | [4 1 1 2] Enter 4 digits, 0–9 QUICK ARM ENABLE [0] Part. 1† Part.2 † 0 = no; 1 = yes *22 RF SYSTEM [0] 0 = none; 1 = 5800 (5881/5882) *23 FORCED BYPASS [0] [0] Part. Part.
*36 ENTRY DELAY 2 (zone type 02) | [60] [60] † † Part. 1 Part. 2 00-99 = entry delay 2 time for each partition; 50 seconds max. for UL installations *37 AUDIBLE EXIT WARNING [1] [1] † Part. 1 Part. 2 † 0 = no; 1 = yes *38 CONFIRMATION OF ARMING DING *39 POWER UP IN PREVIOUS STATE [0] [0] Part. 1 † Part.
*49 SPLIT/DUAL REPORTING [0] 0 = Disable (Backup report only) TO PRIMARY PHONE No. TO SECONDARY PHONE No. 1 = Alarms, Restore, Cancel Others 2 = All except Open/Close, Test Open/Close, Test 3 = Alarms, Restore, Cancel All 4 = All except Open/Close, Test All 5 = All All TO PRIMARY PHONE No. TO PAGING No.
EXPANSION ZONES: Assign zone numbers (Zn) 10–17 to 4219/4229 Auxiliary Wired Loops A–H, if used. ENTER FOR RF ONLY RF zones can use zone numbers (Zn) 10–31 [ [ ZONE DESCRIPTION 4219/4229 Loop A 1st Exp'n Zone or RF Zones ZONE No. (Zn) 1 0 B 1 1 C 1 2 D 1 3 E 1 4 F 1 5 G 1 6 H 1 7 1 8 1 9 2 0 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 2 3 3 RF Zones RF Zones ZONE TYPE (ZT) PART'N ALARM RPT CODE No.
TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (*59Ð*76, & *89): With a 3+1 or 4+1 Standard Format: Enter a code in the first box: 1–9, 0, B, C, D, E, or F. Enter "#+10" for 0, "#+11" for B, "#+12" for C, "#+13" for D, "#+14" for E, "#+15" for F. A "0" ( not "#+10") in the first box will disable a report. A "0" ( not "#+10") in the second box will result in auto matic advance to the next field when programming.
OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR *80, and *81. Applicable only if Relays and/or Powerline Carrier Devicess are to be used. 80 OUTPUT DEVICES – This is an interactive menu mode. Fill in the required data on the worksheet on below and follow * the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Notes: 1. For Relays, field *25 must be programmed for a 4229 (Relays 01 and 02), OR for a 4204 (Relays 01 to 04).
1 * ZONE LISTS FOR OUTPUT DEVICES – This is an interactive mode. Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence. Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, since any list may include any or all of system's zone numbers. Zone List 1: Started or stopped by zone numbers (enter 00 to end entries). , , , , , , , , , ...etc.