Use and Care Manual

15 HOMEDEPOT.COM
Please contact 1-877-527-0313 for further assistance.
Troubleshooting
Before calling for service, please try the suggestions below.
Problem Solution
Dehumidier will not operate
DANGER: ELECTRICAL SHOCK HAZARD
Plug into a grounded 3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
re, or electrical shock.
The dehumidier is turned off. Turn on the dehumidier.
The power supply cord is unplugged. Plug into a grounded
3-prong outlet. See “Pre-Installation” on page 5.
A household fuse has blown, or a circuit breaker has tripped.
Replace the fuse, or rest the circuit breaker. See “Electrical
Requirements” on page 4.
The bucket is not installed correctly. Reinstall the bucket so
that it ts all the way into the dehumidier.
The bucket needs to be emptied. Empty the bucket.
The water level oat is not in place. Remove the bucket. Make
sure the oat is snapped in place. Reinstall the bucket.
The dehumidier suddenly stopped operating and won’t
turn on. Conrm the power is connected, and the bucket is
in place. If the unit still doesn’t operate, call Home Depot for
Warranty service.
Dehumidier runs but does not dehumidify All models have an automatic de-icing function that will shut
off the compressor and allow the fan to run. When the de-
icing function senses the correct operating temperature, the
compressor will cycle back on.
The lter is dirty or obstructed with debris. Clean the lter.
Air coming from the dehumidier is warm Dehumidier will put out warm air under normal operating
conditions.
Dehumidier displays error codes If the dehumidier displays an error code, please contact
customer service.
No water comes out from the Quick connect hose (pump function
model)
The pump function is not activated. Press the Pump button to
activate the pump function. The light will turn on.
The drain hose is not connected correctly. Ensure the hose is
plugged to the bottom of the connector. See Pump Draining
The drain hose is bent or blocked. Ensure the hose is not bent
or blocked
The water lter has not been cleaned. Clean the water lter.