Bypassing Zones
A. General Guidance
You can program the PowerMaxExpress to exclude
(bypass) selected zones, regardless of whether
these zones are "functional" (undisturbed) or "open"
(disturbed). Bypassing permits free movement of
people within certain zones although the system is
armed. It is also used to temporarily remove from
service faulty zones that require repair work. Fire and
temperature zones can not be bypassed.
Remember – zone bypassing compromises security!
Note: Zones will be bypassed throughout one
disarm-arm period only. Disarming the system after
arming will suspend the entire bypassing scheme.
B. Bypassing Procedure
Having entered your user code
successfully (see above
- Entering the User Settings Menu), the display will read:
SET BYPASS
If at this point you click
OK
I
, the number and
state of the first zone containing the first zone will be
automatically displayed. Three states are then made
possible:
Open: The zone is not secured - you can
bypass the zone if you do not wish or know how
to solve the problem right away.
Bypassed: The zone is presently bypassed
(you bypassed it before but have not armed the
system yet).
Functional: If there is nothing wrong with the
zone, its state is described as "Functional
".
Let us assume that Zone 1 is "open" and you wish to
bypass it, and the rest of the zones are functional.
PRESS
RESULTANT DISPLAY
Z01 OPEN
OK
I
(alternating)
KITCHEN
OK
I
<OK> TO BYPASS
Z01 BYPASSED
OK
I
(alternating)
KITCHEN
Z02 FUNCTION
(alternating)
FRONT DOOR
(If you wish
to check the
state of the
next zone)
SET BYPASS
You can select any other item on the USER SETTINGS
menu or quit programming by clicking
. When
<OK> TO EXIT is displayed - click
OK
I
button.
At the end of the bypassing operation, BYPASS blinks:
READY BYPASS or NOT READY BYPASS
This indication will persist as long as the system
remains disarmed, and will disappear once the
system is armed.
Note: BYPASS will alternate in the display with other
messages, such as: TRBL, MEM and MSG.
C. "Unbypass" Procedure
Suppose you wish to restore zone 22 after having
completed the bypassing scheme. Simply re-enter the
SET BYPASS menu (see Bypassing Procedure
above), and click
or until the zone
you wish to "unbypass” in the desired zone is displayed.
Refer to the following steps.
PRESS
RESULTANT DISPLAY
Z22 BYPASSED
(alternating)
LIVING ROOM
<OFF> TO CLEAR
OK
I
Z22 FUNCTION
(alternating)
LIVING ROOM
You may now click and then select any
other item on the USER SETTINGS menu, or click
to quit programming. When <OK> TO EXIT
appears - click
OK
I
.
Reviewing the Bypassed Zone List
Having entered your user code successfully (see above -
Entering to the User Settings Menu), the display will read:
PRESS
RESULTANT DISPLAY
SET BYPASS
Enter user code
SHOW BYPASS
OK
I
BYPASS LIST
If at this point you click
OK
I
, the number, state and
name of the first bypassed zone will be displayed.
You can now click
repeatedly to review all
bypassed zones, in ascending numerical order. When
done, clicking
will get you back to SHOW
BYPASS and clicking
will get you back to
<OK> TO EXIT.