Specifications

32 D-302989
Alarms
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
1
st
digit
4 4 4 4 444 4 4 4 4 4444555555555 5 5 5 5 5
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E
Restorals
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
1
st
digit
C C C C CCC C C C C CCCCDDDDDDDDD D D D D D
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E
Supervisory trouble
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
st
digit
6 6 6 6 666 6 6 6 6 6666777777777 7 7 7 7
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D
Low Battery
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28
1
st
digit
8 8 8 8 888 8 8 8 8 8888999999999 9 9 9 9
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D
Forced Arming – 8 users
User No. 1 2 3 4 5 6 7 8
1
st
digit A A A A A A A A
2
nd
digit 1 2 3 4 5 6 7 8
Zone Bypass
Zone # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29
1
st
digit
A A A A AAA A A A A AAAABBBBBBBBB B B B B B
2
nd
digit
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E
Panic / 24 Hours - 8 users
User No. 1 2 3 4 5 6 7 8 Panic CP Duress
1
st
digit 2 2 2 2 2 2 2 2 2
2
2
nd
digit 1 2 3 4 5 6 7 8 9 A
Arm HOME and AWAY (Closing)
User No. 1 2 3 4 5 6 7 8 Cancel alarm Recent Close
1
st
digit E E E E E E E E E E
2
nd
digit 1 2 3 4 5 6 7 8 9 C
Disarm (Opening)
User No. 1 2 3 4 5 6 7 8
1
st
digit F F F F F F F F
2
nd
digit 1 2 3 4 5 6 7 8
Trouble
Event Fuse
Fail
Fuse
Restore
Jamming Jamming
Restore
AC
Failure
AC
Restore
CPU Low
Battery
CPU Low
Battery Restore
CP
Tamper
1
st
digit 2 2 2 2 1 1 1 1 1
2
nd
digit C D E F 1 2 3 4 6
Event CP Tamper
Restore
No Active COMM. &
LINE Restore
Enter Test Exit Test Auto Test
1
st
digit 1 1 1 1 1 1
2
nd
digit 7 8 A D E F