Specifications

12 D-302989
4.3 DEFINING ZONE TYPES, NAMES & CHIME ZONES
This mode allows you to assign one of 15 zone types to
each of the system's 29 (wireless & wired) zones. In
addition, it also allows you to assign a name to each zone
and determine whether the zone will operate as a chime
zone (only while the system is in the disarmed
or Home
arming state). When a chime zone is triggered, chime
melody or zone name is heard (there are 2 selectable
chime modes - Melody chime or Chime Off).
A list of factory defaults is printed in table 1. You may fill
out the blank columns even before you start and proceed
to program according to your own list.
Remember!
A delay zone is also a perimeter zone by definition.
Zone types are fully explained in Appendix C.
ZONE No: - -
Zxx: TYPE -
[Zone No.] (e.g. 05)
1. Inter-follow
2. Perimeter
Zxx: NAME - -
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet
(*)
(*)
4. Delay 1
5. Delay 2
6. 24h silent
7. 24h audible
8. Fire
9. Non-alarm
10. Emergency
3. Perim-follow
(see list above)
11. Gas
12. Flood
13. Interior
3. DEFINE ZONES
[installer code]
USER SETTING
ENTER CODE
2.
ENROLLING
INSTALLER MODE
<OK> TO EXIT
14. Temperature
15. Home/Delay
Zxx: CHIME
Melody-chime
Chime off
(*)
Zxx: KEY ON/OFF
z-key enable
z-key disable
(*)
(**)
OPTIONAL
WALK TEST
READY
(First display)
If Non-alarm is selected
Attic
Back door
Basement
Bathroom
Bedroom
Child room
Closet (
UK:
Conservatory)
Den (
UK:
Playroom)
Selectable Zone Names
Dining room
Downstairs
Emergency
Fire
Front door
Garage
Garage door
Guest room
Hall
Kitchen
Laundry room
Living room
Master bath
Master bdrm
Office (UK: Study)
Upstairs
Utility room
Yard (
UK:
Garden)
Custom 1
Custom 2
Custom 3
Custom 4
Custom 5
31 zone names can be selected, 26 fixed names and 5 custom names (defined by
the installer - see chap. 4.9):
Figure 4.3 - DEFINE ZONES Flow Chart
* The currently saved option is displayed with a dark box at the right side. To review the options, repeatedly click
or
button, until the desired option is displayed, then click
OKI
(a dark box will be displayed at the right side).
** Key ON/OFF is an optional function that enables you to arm or disarm the system via zones 21-28, 29 or 21-29, provided
that "non-alarm" was pre-defined for these zones.
Table 1 - DEFAULT AND PROGRAMMED ZONE DEFINITIONS
Zone Zone Type Zone Name Chime (melody
No. Default Programmed Default Programmed Zone Name or Off) (*)
1 Delay 1 Front Door
2 Delay 1 Garage
3 Delay 2 Garage Door
4 Perimeter Back Door
5 Perimeter Child Room
6 Interior Office
7 Interior Dining Room
8 Perimeter Dining Room
9 Perimeter Kitchen
10 Perimeter Living Room