Specifications
D-302754 PowerMaxComplete Installer's Guide 15
Table 1 - DEFAULT AND PROGRAMMED ZONE DEFINITIONS
Zone Zone Type Zone Name Chime (melody Partition
No. Default Programmed
Default Programmed Zone Name or Off) (*)
1
Delay 1
Front Door
2
Delay 1
Garage
3
Delay 2
Garage Door
4
Perimeter
Back Door
5
Perimeter
Child Room
6
Interior
Office
7
Interior
Dining Room
8
Perimeter
Dining Room
9
Perimeter
Kitchen
10
Perimeter
Living Room
11
Interior
Living Room
12
Interior
Bedroom
13
Perimeter
Bedroom
14
Perimeter
Guest Room
15
Interior
Master Bedroom
16
Perimeter
Master Bedroom
17
Perimeter
Laundry Room
18
Perimeter
Master Bathroom
19
Perimeter
Basement
20
Fire
Fire
21
Fire
Fire
22
Emergency
Emergency
23
Emergency
Emergency
24
24 h / silent
Basement
25
24 h / silent
Office
26
24 h / audible
Attic
27
24 h / audible
Den
28
non
-
alarm
Yard
29
non
-
alarm
Hall
30
non
-
alarm
Utility room
* Note: All zones are Chime-off by default. Enter your own choice in the last column and program accordingly.
4
44
4.
..
.4 DEFINING CONTROL PANEL PARAMETERS
4 DEFINING CONTROL PANEL PARAMETERS4 DEFINING CONTROL PANEL PARAMETERS
4 DEFINING CONTROL PANEL PARAMETERS
4.4.1 Preliminary Guidance
This mode allows you to customize the control panel and
adapt its characteristics and behavior to the requirements
of the particular user. An illustrated process is shown in
figure 4.4. In this illustration, each selected option is
displayed with a dark box at the right side. To review the
options, repeatedly click
or button, until
the desired option is displayed, then click SHOW/OK button
.
4.4.2 Entry Delays 1&2
(Fig. 4.4, location 01, 02). Two different entry delays allow
the user to enter the protected site (while the system is in
the armed state) via 2 specific doors and routes without
causing an alarm.
Following entry, the user must disarm the control panel
before the entry delay expires. Slow-rate warning beeps
start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate
increases. Locations No. 1 (entry delay 1) and 2 (entry
delay 2) allow you to program the length of these delays.
Available options for each delay are: 00s, 15s, 30s, 45s,
60s , 3m and 4m.
Note: For UL installation entry delay should be up to 45 sec.
4.4.3 Exit Delay
(Fig. 4.4 location 03). An exit delay allows the user to arm the
system and leave the protected site via specific routes and
doors without causing an alarm. Slow-rate warning beeps
start sounding once the arming command has been given,
until the last 10 seconds of the delay, during which the
beeping rate increases. Location No. 3 allows programming of
the exit delay length. Available options are: 30s, 60s, 90s,
120s, 3m, 4m.
Note: For UL installation exit delay should be up to 120 sec.
4.4.4 Bell Time
(Fig. 4.4, location 04). Here you select the length of time
the bell (or siren) is allowed to function upon alarm. The
bell time starts upon activation of the siren. Once the bell
time expires, the siren is automatically shut down.
Available options are: 1, 3, 4, 8, 10, 15 and 20 minutes.
Note: Bell Time is defined for the entire alarm system and
not per partition.
4.4.5 Abort Time
(Fig. 4.4 location 05). Here you select the length of time
allowed by the system to abort an alarm (not applicable to
alarms from FIRE, 24H SILENT, EMERGENCY, GAS
FLOOD and TEMPERATURE zones). The
PowerMaxComplete is programmed to provide an “abort
interval” that starts upon detection of an event. During this
interval, the buzzer sounds a warning but the siren remains
inactive and the alarm is not reported. If the user disarms
the system within the allowed abort interval, the alarm is
aborted.
Available options are: 00s, 15s, 30s, 45s, 60s, 2m, 3m,
4m.