Specifications
D-301680  1 
MCS-730/MCS-730 AC
Fully / Mains Powered Wireless Outdoor Siren 
Installation Instructions 
1. INTRODUCTION 
The MCS-730, powered by 1 or 2 (optional) non-rechargeable batteries, 
is fully wireless outdoor siren, designed for installation in areas in which 
wiring action is difficult or impossible. It is compatible with control panels 
such as PowerMax Pro, PowerMaxComplete, PowerMaxExpress or 
Visonic newer panels (not compatible with PowerMax+ and PowerMax 
control panel). 
The MCS-730 AC is similar to MCS-730 but It is powered by an External 
9VAC Adaptor and non-rechargeable backup battery - enables very 
long operation time without replacing the battery. The MCS-730 AC 
complies with PowerMax+ also. 
Features 
•  Siren and strobe light activation: The siren produces a strong 
alarm noise and emits flashing light to deter intruders and guide 
police to the site. 
 Notes: 
  The duration of the siren's alarm is controlled from the control panel 
by setting the "Bell Time" option (refer to alarm system installer 
guide, par. 4.4) and should be set according to local authorities 
requirements. 
  The strobe light operates (every 1 second) for 20 minutes after 
siren stops or until the system is disarmed, whichever occurs first. 
•  2 Types of alarm indication 
The siren produces different alarm signals for Burglar and Fire. 
•  Squawk indication: Squawk (beep) sounds can be used to 
indicate alarm system arming (1 squawk) and disarming (2 
squawks) by a keyfob (squawk can be enabled from the control 
panel User menu). 
•  Tamper / supervision failure indication: Siren is equipped with 
tamper protection, which produces alarm if a burglar attempt to 
open the siren's cover or remove siren from wall. 
•  Low battery voltage alert 
The siren reports a low battery message to the alarm system when 
battery is about to drain. After low voltage is reported, at least 2 
siren alarms are possible before the siren is totally inactive. 
•  Strobe Light Color: The siren can be purchased with red, blue, 
amber or transparent lens, according to the desired strobe light color. 
•  Siren activity LED: A flashing LED (optional, at the bottom of the 
siren front panel) indicates siren activity (can be disabled by an 
internal jumper, see fig. 3, step 8) 
Fig. 1a - External View 
Fig. 1b – Mounting Position 
IMPORTANT! The MCS-730/MCS-730 AC siren must be installed 
on the wall in a vertical position with the screw pointing to the floor 
only
, as illustrated in Figure 1b. The importance of correct 
positioning of the MCS-730/MCS-730 AC is to enable the siren to 
function as a waterproof device. 
•  2-way full supervision 
The siren is fully supervised, 2-way communication device. It 
periodically transmits its status signal to the alarm system. 
•  Installation diagnostics 
The transmitted signal strength can be measured during the 
installation (refer to the alarm system Installer guide, par. 5.2 – 
Diagnostic Test). 
•  Self-test function 
Upon pressing the self test switch, siren functional check is performed - 
low level sounds and flash light indicate that the siren is serviceable. 
MCS-730 /
MCS-730 AC
Hard wired detector
Smoke detector
Wireless transmitter
Door or window
open/close detector
Motion detector
Remote commander
PowerMax+ /
PowerMax Pro /
PowerMaxComplete /
PowerMaxExpress
Figure 2- Typical Integration with the Alarm System
2. SPECIFICATIONS 
Siren Type: One Piezo 109 db. Sound Pressure Level @ 1m, 1.8-3.5 
kHz, sweep frequency 7 Hz. Additional piezo is optional. 
AC Power Supply Adaptor (MCS-730 AC only):
120 VAC, 60 Hz / 9 VAC, 0.35 A min. (in the U.S.A.) 
230 VAC, 50 Hz / 9 VAC, 0.35 A min. 
Battery:  3.6V/14.5A/H Lithium battery (EVE ER34615M/w200), 
Visonic assembly cat. No. 0-9912-K. 
Caution! Risk of explosion if battery is replaced by an incorrect type. 
Dispose of used battery according to the manufacturer's instructions. 
Battery Life Time:
 3 years (taking into consideration a typical alarm 
of 4 minutes Piezo + strobe operation per week). 
Current Consumption: Standby - 250µA average, Operation - 
300mA average. 
Compliance with Standards: EN 50131-1 Grade 2 Class 4, 
EN50131-4, EN301489, EN50130-4, EN50130-5, ETSI EN 300 220,  
IP55, CFR47 part 15. Designed to comply with Belgium / TO14, 
Sweden / SSF1014. 
Operating Frequency (MHz): 315, 433.92, 868.95 
Supervision Time: 5 minutes 
Strobe Light: 
Pulsed @ 1 sec. 
Dimensions (LxWxD): 295x186x63mm (11-5/8 x 7-5/16 x 2-1/2 in) 
Color: White (with red, blue, amber or transparent lens) 
Operating Temperature: 
-33°C to 70°C (-27.4°F to 158°F), RH 
humidity 75%. 
Weight (including battery): 970g (34 oz) 
Note:  The manufacturer is not responsible for any radio or TV 
interference caused by unauthorized modifications to this equipment. 
Such modifications could void the user's authority to operate the 
equipment. 
Interference Prevention 
This device complies with FCC Rules Part 15. Operation is subject to two 
conditions: (1) This device may not cause harmful interference, and (2) this 
device must accept any interference that may be received or that may cause 
undesired operation. 
The digital circuit of this device has been tested and found to comply with the limits 
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are 
designed to provide  reasonable protection against harmful interference in 
residential installations. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio and television reception. 
However, there is no guarantee that interference will not occur in a particular 
installation. If this device does cause such interference, which can be verified by 
turning the device off and on, the user is encouraged to eliminate the interference 
by one or more of the following measures: 
–  Re-orient or re-locate the receiving antenna. 
– Increase the distance between the device and the receiver. 
– Connect the device to an outlet on a circuit different from the one which 
supplies power to the receiver. 
– Consult the dealer or an experienced radio/TV technician. 
Changes or modifications not expressly approved by Visonic Ltd. could void 
the user's authority to operate the equipment. 