Specifications
30  D-300885 
4/2 Event Codes 
Note: The report to central station is on the following zones: First wireless siren - zone 31, second wireless siren - zone 32, 
GSM - zone 33, first 2-way keypad (MKP-150/MKP-151) - zone 35, second 2-way keypad (MKP-150/MKP-151) - zone 36.
Alarms 
Zone #  1  2 3  4  5 6 7 8  9  10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 
1
st
 digit 
4 4 4 4 444 4 4 4 4 4444555555555 5 5 5 5 5 5 
2
nd
 digit 
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F 
Restorals 
Zone #  1  2 3  4  5 6 7 8  9  10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 
1
st
 digit 
C C C C CCC C C C C CCCCDDDDDDDDD D D D D D D 
2
nd
 digit 
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F 
Supervisory trouble 
Zone #  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 
1
st
 digit 
6 6 6 6 666 6 6 6 6 6666777777777 7 7 7 7 
2
nd
 digit 
1 2 3 4 567 8 9 A B CDEF123456789 A B C D 
Low Battery 
Zone #  1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 
1
st
 digit 
8 8 8 8 888 8 8 8 8 8888999999999 9 9 9 9 
2
nd
 digit 
1 2 3 4 567 8 9 A B CDEF123456789 A B C D 
Forced Arming – 8 users 
User No.   1 2 3 4 5 6 7 8 
1
st
 digit  A A A A A A A A 
2
nd
 digit  1 2 3 4 5 6 7 8 
Zone Bypass 
Zone #  1  2 3  4  5 6 7 8  9  10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 
1
st
 digit 
A A A A AAA A A A A AAAABBBBBBBBB B B B B B B 
2
nd
 digit 
1 2 3 4 567 8 9 A B CDEF123456789 A B C D E F 
Panic / 24 Hours - 8 users 
User No.   1 2 3 4 5 6 7 8 Panic CP  Duress  
1
st
 digit  2 2 2 2 2 2 2 2 2 
2
2
nd
 digit  1 2 3 4 5 6 7 8 9  A 
Arm HOME and AWAY (Closing) 
User No.   1 2 3 4 5 6 7 8 Cancel alarm Recent Close 
1
st
 digit  E E E E E E E E E  E 
2
nd
 digit  1 2 3 4 5 6 7 8 9  C 
Disarm (Opening) 
User No.   1 2 3 4 5 6 7 8 
1
st
 digit  F F F F F F F F 
2
nd
 digit  1 2 3 4 5 6 7 8 
Trouble 
Event   Fuse 
Fail 
Fuse 
Restore
Jamming Jamming 
Restore 
AC 
Failure 
AC 
Restore
CPU Low 
Battery 
CPU Low 
Battery Restore 
CP 
Tamper 
1
st
 digit  2 2 2  2 1 1 1  1  1 
2
nd
 digit C D E  F 1 2 3  4  6 
Event   CP Tamper 
Restore 
No Active  COMM. & 
LINE Restore 
Enter Test  Exit Test  Auto Test 
1
st
 digit 1  1  1 1 1 1 
2
nd
 digit 7  8  A D E F 