Specifications
26  D-300885 
4.14 CALLING UPLOAD/DOWNLOAD SERVER 
Note: 
This option is only used during the installation of panels 
monitored by compatible central stations. 
This option allows the installer to initiate a call to the 
upload/download server. The server uploads the 
PowerMaxComplete configuration to its data base and can 
unload predefined parameters to the PowerMaxComplete . 
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
Displayed for half
a minute approx.
accompanied by sad
(failure) melody
READY 00:00
USER SETTINGS
NORMAL MODE
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
5. DEFINE COMM
[installer code]
INSTALLER MODE
4. DEFINE PANEL
COMMUNICATING TEL # NOT DEFINED
DOWNLOADING DIAL ATTEMPT FAIL
DOWNLOAD OK DOWNLOAD FAILED
Displayed during
dialing process
If UL/DL server
tel. # was not
defined before
(see par. 4.5.34)
If UL/DL server
tel. # is already
defined (see
par. 4.5.34)
Dialing
OK
Dialing
failed
Download
OK
Download
failed
Displayed during
download process
Displayed for half
a minute approx.
accompanied by happy
(success) melody
8. DEFINE OUTPUTS
9. DEFINE VOICE
10. DIAGNOSTICS
11. USER SETTINGS
12. FACTORY DEFLT
13. SERIAL NUMBER
<OK> TO EXIT
14. START UL/DL
6. DEFINE GSM
Figure 4.14 – Start UL/DL 
5. TESTING PROCEDURES 
5.1 Preparations 
Make sure all windows and doors are closed. If all zones 
are secured (undisturbed), the display should read: 
  READY  HH:MM 
If the display is “NOT READY”, query the control panel by 
pressing the 
 button repeatedly. The source(s) 
of the problem(s) will be displayed and read aloud. Take the 
necessary measures to eliminate the problem(s) before 
testing the system (see next paragraph). 
5.2 Diagnostic Test 
To verify proper function of all detectors in the system, a 
comprehensive diagnostic test is required. To perform this 
test, refer to figure 4.10. 
5.3 Keyfob Transmitter Test 
Initiate transmission from each transmitter enrolled as a 
keyfob unit (according to the list in Table A2, Appendix A). 
Use each transmitter to arm the control panel AWAY and 
immediately disarm it. Upon pressing the keyfob unit’s 
AWAY key, the ARM indicator should light. 
The display should respond as follows: 
ARMING AWAY  
  PLEASE EXIT NOW 
The exit delay beeps will begin. 
Press the keyfob unit’s DISARM (
) key. The ARM indicator 
should extinguish, the announcement “Disarm, ready to arm" 
should be heard and the display should revert to: 
  READY  HH:MM 
Test the AUX button in each keyfob in accordance with the 
information noted in Table A.2, Appendix A. Verify that the 
AUX button performs its duty as programmed. 
 If the AUX (
@) button is defined as “STATUS”, system 
status should be displayed and announced upon 
pressing the button. 
  If the AUX (
@) button is defined as “INSTANT”, press 
the AWAY button and then the AUX button. The 
response should be: 
  ARMING INSTANT 
(alternating)
  PLEASE EXIT NOW 
and the exit delay beeps will start. Press the DISARM ( ) 
key immediately to disarm. 
  If the AUX (
@) button is programmed as “PGM” and 
permitted to activate the PGM output, pressing (
@) 
should activate the device wired to the PGM output. 