Specifications
D-300885  23 
<OK> TO EXIT
5. DEFINE COMM.
4. DEFINE PANEL
3. DEFINE ZONES
2. ENROLLING
1. NEW INSTL CODE
ENTER CODE
INSTALLER MODE
USER SETTINGS
NORMAL MODE
READY 00:00
[installer code]
6. DEFINE GSM
5. 4th SMS number
1. GSM INSTALL 2. 1st SMS number 3. 2nd SMS number 4. 3rd SMS number
6. REPORT SMS 7. GSM line failure
don’t report
2 minutes
all
all (-op/cl)
all (-alerts)
alarms
alerts
op/cl
Installed
Not installed
xxxxxxxxxxxxxxxx
(Enter GSM No.)
xxxxxxxxxxxxxxxx
(Enter GSM No.)
xxxxxxxxxxxxxxxx
(Enter GSM No.)
xxxxxxxxxxxxxxxx
(Enter GSM No.)
5 minutes
15 minutes
30 minutes
disable report
5. 4th SMS number 6. REPORT  SMS
all
all (-op/cl)
all (-alerts)
alarms
alerts
op/cl
xxxxxxxxxxxxxxxx
(Enter GSM No.)
disable report
8. GSM line purpose
SMS only
GSM is primary
GSM only
GSM is backup
Figure 4.6 - DEFINE GSM 
4.6.4 GSM Line Failure Reporting 
Here you determine whether GSM network failure will be 
reported after 2 min., after 5 minutes, after 15 min., or after 
30 minutes. Available options: don't report, 2 min, 5 min, 
15 min, or 30 min. 
4.6.5 GSM Line Purpose 
Define whether the GSM unit will serve as a backup for the 
regular telephone line, as a primary communication 
channel or as the only telephone channel or for sending 
SMS only. Available options are: GSM is backup, GSM is 
primary, GSM only or SMS only. 
4.8 DEFINING OUTPUT PARAMETERS 
4.8.1 Preliminary Guidance 
This mode allows you: 
a. Events/conditions selection under which PGM 
(programmable) output will function. 
b. Selection of the internal siren or STROBE light (that will 
be activated according to system programming). 
4.8.2 Define PGM 
For the PGM output, you can select disable, turn on, turn 
off or pulse active (turn on for predefined period, selected 
by PULSE TIME), as follows: 
  BY ARM AWAY (upon AWAY arming). 
  BY ARM HOME (upon HOME arming). 
  BY DISARM (upon disarming). 
  BY MEMORY (activated upon registration of an alarm in 
the memory, turned off upon memory clearing). 
  BY DELAY (during exit / entry delays). 
  BY KEYFOB (upon AUX button pressing in the keyfob 
transmitter / MCM-140+, if “PGM” is selected in “Define 
Panel” menu, locations 17 and 18). 
  BY ZONES (by disturbance in each
 of 3 selected zones, 
irrespective of arming / disarming). If you select toggle, 
the PGM output will be turned on upon event 
occurrence in these zones and will be turned off upon 
next event occurrence, alternately. 
  BY LINE FAIL: PGM output is ON if telephone line is 
disconnected. 
4.8.3 Defining INT/STRB 
Here you determine whether the INT output will be used for an 
internal siren or for a strobe. If strobe is selected, the INT 
output will be activated when an alarm occurs until the system 
is disarmed and rearmed again (i.e. clearing alarm memory). 
4.8.4 PGM General Definition 
Here you determine the PGM LOCKOUT TIME - daytime limits 
between which PGM output (that is controlled by sensors) will 
be off even when the associated sensors are triggered. To 
disable the lockout time, the START and STOP times should 
be identical (see figure 4.8). 