User guide
Chapter 6: Data Details Tables
48 DE5450S Remote Programmer Guide Rev. 9
6.21 Panel Status/Trouble
This table is applicable to the PowerG models.
The Panel Status/Trouble screen displays diagnostic information that is uploaded
from the Control Panel.
A Yes indication alerts that a condition exists that needs checking. A No indication
means that the condition is normal.
Condition Description
STATUS 1/
STATUS 2
Armed/Disarmed, Ready/Not Ready
LOW BATTERY Control Panel’s battery needs replacement or
is not connected.
NOT ACTIVE Control Panel is not transmitting.
FUSE TROUBLE Fuse has shut the current circuit and will
reset automatically.
LINE FAILURE Telephone line or network (such as GSM) is
disconnected.
COMMUNICATION
FAILURE
Communication failure between the control
panel and the monitoring station.
TAMPER OPEN Control panel has been opened or tampered
with.
JAMMED
TROUBLE
Control panel transmissions are being
jammed.
TAMPER ALARM Control panel has been opened or tampered
with. The alarm. The alarm state ends only
after disarming and then rearming the
system.
OTHERS Other system faults.
PROTOCOL
VERSION
System’s communication protocol version.