User guide

Chapter 6: Data Details Tables
DE5450S Remote Programmer Guide Rev. 9 37
To Perform a Periodic Test
1. Click the Periodic Test icon on the toolbar.
2. Press the Arm AWAY button.
3. Make sure that Testednow appears in the Walk Test column.
To Delete a Keyfob
1. In the Keyfob Enrollment table, click the Action button of the keyfob to
be deleted.
2. From the dialog box, select the Delete Device radio button.
3. Click the Send to Panel button.
4. A new dialog box opens asking Are you sure?; click Yes.
5. Click Close.
The keyfob is now deleted from the system.
6.15 Repeater Enrollment
A repeater increases the communication range between the control panel and
detectors and other transmitting devices separated by farther distances.
This table displays information about the installed repeaters. The data
includes the zone number and RF ID of the installed repeater, enrollment
status, the device type (repeater), received signal strength indication (24-
hour and current RSSI) quality of the device (Strong; Good; Poor; or Not
OK), device configuration and walk-test.
To Pre-enroll a Repeater on the Remote Programmer
1. Login to the Remoter Programmer.
2. In the Repeater Enrollment table, click an Unregistered Action button
.
3. In the dialog box that opens, make sure the Add Device radio button is
selected and enter the siren ID.