User guide
16 D-303503 MKP-160 User's Guide
Notes:
A zone which is BYPASSED and NOT READY is shown as BYPASSED (
).
When "00" appears on the Zone # display, this indicates a NOT READY state in the alarm
system that is not related to any detector, for example, "tamper open" in a keypad or control
panel.
If all zones are READY and "not bypassed", the button is disabled.
3.4 Bypassing Zones
A zone can by bypassed by pressing the key until the zone number is shown on the zone #
display (marked "4" in the "Quick Reference Guide") followed by the
key.
Note: Zone bypassing on the MKP-160 unit can be operated only if Bypass was enabled via
the control panel (see PowerMax Installer Guide).
3.5 Controlling Home Automation Devices
To operate home automation devices, see the table below.
Note: Make sure that the relevant PGM and X-10 outputs are configured correctly; refer to
the “OUTPUTS” menu in the control panel’s Installer Guide.
Step X-10 device ON PGM device ON X-10 or PGM
device OFF
X-10 or PGM
device TOGGLE
1
(~2sec)
2
…
[1 to 15]
…
[P0]
[PGM
P0] or
[X-10
1 to 15]
[PGM
P0] or
[X-10
1 to 15]
3
The keyprox's LED blinks red once to indicate transmission of the command to the control
panel. The LED and the buzzer then indicate the control panel's response – see “System
Status and Indications” in section 3.3.
Note:
• Long press (more than 2 sec.) of the button initiates the X-10 function and the
PGM/X-10 display (marked "4" in the "Quick Reference Guide") will read "01". This
number is incremented by 1 upon each press of the key.
• Short press of the button initiates the PGM function and the PGM/X-10 display will
read "P0" with the key.