User guide

10 D-303503 MKP-160 User's Guide
Define whether or not the control panel will monitor supervision
messages sent by the keyprox.
Options settings: disable and enable (default).
Define whether or not the keyprox will sound the exit and entry
beeps or whether the keyprox will sound the beeps only when the
system is armed AWAY and not when it is armed HOME.
Note:
When the screen saver is active during an exit/entry delay,
the MKP-160 device will not sound exit-entry beeps (exit-entry
beeps are sounded only through the control panel during this
time). If the MKP-160 returns to normal display during the
entry/exit delay, it will continue to sound the exit-entry beeps until
the next time the screen saver is activated or until the end of the
exit/entry delay, whichever first.
Options settings: off (default); off when home and on.
Define the volume level of the sounder.
Options settings: low, mid (default) and high.
Define if Trouble or Memory events in the control panel will be
indicated on the LCD keyprox.
Options settings: enable (default) and disable.
2.6 Enrolling Proximity Tags
You can enroll proximity tags in the PowerMax control panel either through the MKP-160
touch screen keyprox, as described below, or through the PowerMax control panel, as
described in the corresponding section of the control panel's User or Installer Guide.
Each proximity tag corresponds to its User Code. Therefore, be sure that a corresponding
User Code is programmed for each enrolled proximity tag (code "0000" is not allowed). For
example, "Tag no : 2" must be assigned to User Code 2 and " Tag no : 8" must be assigned
to User Code 8. Partition authorization of each proximity tag is identical to that of the
corresponding User Code. For example, if User Code 3 is set to Partitions 1 and 3,
"Tag no : 3" will also be set to Partitions 1 and 3.
Enrolling Proximity Tags in the PowerMax Panel through the MKP-160 Keyprox
Step Action LCD Display
1
Enter the Installer menu of the control panel and
go to “
2.ENROLLING
2.ENROLLING2.ENROLLING
2.ENROLLING
2
Select "ENROLL PROX TAG" Option
3
Select the Prox Tag number for enrollment
SUPERVISION
Tag no : 8
Tag no :
ENROLL PROX TAG
2.ENROLLING
SOUNDER VOLUME
EXIT-ENTRY BEEPS
SHOW MEM/TRBL