USER GUIDE K P - 1 6 0 K e y p a d U s e r ' s www.visonic.
Quick Reference Guide 3 1 4 5 2 29 6 28 25 27 26 23 24 8 7 9 10 6 7 16 11 12 6 7 15 14 13 19 17 21 20 18 19 22 1. Present Prox Tag 2. Volume indication 3. System status (NOT READY/BYPASS) 4. Volume-level, Zone #, PGM / X-10 display 5. PGM / X-10 indication 6. Partition status indication 7. Partition Selection 8. DISARM 9. ARM HOME / QUICK ARM HOME 10. ARM AWAY / QUICK ARM AWAY 11. LATCHKEY 12. Mute exit beeps 13. Volume control 14.
KP-160 PG2 Touch Screen Keyprox User’s Guide Table of Contents 1. INTRODUCTION ............................................................................................................. 2 2. INSTALLATION ............................................................................................................... 3 2.1 Inserting Battery..................................................................................................... 3 2.2 Closing Battery Compartment Cover ..........................
1. INTRODUCTION KP-160 PG2 is a 2-way wireless PowerG touch screen keyprox for the PowerMaster family control panels. The KP-160 PG2 enables most common everyday user functions: Arm and Disarm the alarm system. Initiate Emergency, Fire and Panic alarms. Control home automation devices. Review system status. Perform programmable predefined functions. KP-160 PG2 is operated by proximity tags.
2. INSTALLATION 2.1 Inserting Battery CAUTION! Risk of explosion if battery is replaced by an incorrect type. Dispose of used battery according to manufacturer's instructions. Figure 1 – Battery Insertion Insert two 1.5V batteries in each slot while ensuring battery polarity. 2.
Wall-mounted Installation (Using Battery Cover without Tamper Hole – see "A") Figure 3 - Battery Cover Mounting (part b) A. Tamper B. DC Power Connection 2.3 Wall Mounting Options The KP-160 PG2 unit mounting options are illustrated in the following drawings. Wall Mounting Figure 4a – Wall Mounting 1. Drill 3 mounting holes 2. Position the bracket and secure with 3 screws 4 3. Attach the unit to the bracket 4.
Wall Mounting with External Electrical Connector Figure 4b – Wall Mounting with External Electrical Connector 1. Secure bracket with 2 screws as shown in the two drawings above. 2. Attach the unit to the bracket. 3.
2.4 Enrolling the KP-160 PG2 Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu. A flowchart of the procedure is provided below. Step Action LCD Display 1 Enter the Installer menu and select “02:ZONES/DEVICES” 02.ZONES/DEVICE 2 Select "ADD NEW DEVICE" Option See Note ADD NEW DEVICES MODIFY DEVICES 3 Enroll the device or enter the 7-digit code that appears on the device's sticker.
Notes: 1. Every 5 minutes the keyprox performs a communication test session with the control panel (i.e. "Supervision signal) to check the integrity and quality of the Radio link. If the keyprox does not report a supervision signal at least once within a predefined time, a “MISSING” trouble alert is initiated. Therefore, if you take the keyprox out of the protected premises, switch the Supervision OFF to avoid the trouble alert. 2. For UL Listed product, set to “ON”.
Stop Beeps: Control panel and other devices in the system (such as keyproxs, sirens etc.) will stop beeping during the exit delay. Skip exit delay: Stop the exit delay immediately. X-10 (PGM): Activate the appliance controlled by the chosen X-10 unit(s) or the device wired to the PGM output. For more details on configuring the X-10/PGM output functions, see the corresponding sections of the control panel’s Installer Guide (“OUTPUTS” menu) and User Guide (“SCHEDULER” menu).
3. USING THE TOUCH SCREEN KEYPROX 3.1 Arming and Disarming the System Step Operation User Actions (1) Select a PARTITION (if Partition is enabled) 2 Arm AWAY Optional 1 Any combination of + Arm HOME Optional ] [ ] [ ] Quick arm AWAY (If Quick Arm is enabled) ( 2 sec.) (3) INSTANT ( 2 sec.) (After arming HOME/ AWAY) LATCHKEY (5) (7) (After arming AWAY) (4) (4) (4) (3) Quick arm HOME (If Quick Arm is enabled) 4 Optional + The selected key blinks.
7. LATCHKEY is available only if the LATCHKEY feature is enabled in the PowerMaster control panel (see PowerMaster Installer Guide).You can perform the LATCHKEY and INSTANT functions, one after the other. The order is not important. LATCHKEY and INSTANT functions can be operated only during exit delay. While in INSTANT / LATCHKEY, the small circle icon on the upper right side of the INSTANT / LATCHKEY icon lights. Notes: 1. Latchkey Arming is supplemental in UL installations. 2.
Arming Indications The table below lists the Arming indication keys and their definition.
Number Indication [1] + What it Means Volume level PGM/X-10 control mode. System is armed in LATCHKEY mode. Exit beeps are shut off. This mode disables when the exit delay is over. [2] System is armed in the INSTANT mode. A message is waiting in the system. The control panel is presently in "INSTALLER MODE" or "USER SETTINGS". Memory / Alarm in partition or system. The partition / system has an active trouble [3] status that needs to be reviewed and cleared. AC failure.
Zone Status Indications To view the zone numbers of enrolled detectors that are in NOT READY ( ) or BYPASSED state ( ), repeatedly press the key. Upon each press of the key, the next zone number appears on the Zone # display (marked "4" in the "Icon and Key Indications" Figure). To view the zone numbers that are assigned to a Partition, press the desired Partition number ( / / ) followed by the key.
3.4 Bypassing Zones A zone can by bypassed by pressing the key until the zone number is shown on the zone # display (marked "4" in the "Icon and Key Indications" Figure) followed by the key. Notes: 1. Zone bypassing on the KP-160 PG2 unit can be operated only if Bypass was enabled via the control panel (see PowerMaster Installer Guide, section 3.5.2 "Configuring Arming/Disarming and Exit/Entry Procedures"). 2. For UL Listed product, manual bypass must be enabled. 3.
3.6 Other Functions Output Function Actions AUX Function Response Enrollment: Long key press (more than 5 sec.) until green LED lights and then release key. Back to Factory: Long key press (more than 7 sec.) to reset the KP-160 PG2 device to factory default settings. Cancels current operation: Short key press Volume control Changes the volume level upon each key press. Volume level alternates between 1, 2, 3, 0 Mute exit beeps Mutes the exit beeps; small circle key will appear above the key.
Telefication BV has certified only the 868 MHz variant of this product. UK: This product is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2. DD243 and BS8243 USA: CFR 47 part 15 Canada: RSS 210 RFID Tags: ISO-18000-2 (125 kHz) The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical brochure.
Arming and Disarming the System Step Basic Arming User Actions 1 Select a PARTITION (if Partition is enabled) Any combination of 2 3 4 Keyboard & Panel Response The selected key blinks. Arm AWAY (3) + [present TAG] or [Enter code] The selected key and the Present Arm HOME (2) + [present TAG] or [Enter code] Disarm (OFF) (1) + [present TAG] or [Enter code] Quick arm AWAY (if Quick Arm is enabled) (3) (≈ 2 sec.) Quick arm HOME (if Quick Arm is enabled) (2) (≈ 2 sec.
Additional PowerG Products Wireless Fire Detector with Internal Siren Wireless Curtain-type Detector Wireless PIR/ Pet-immune Detector Wireless PIR Camera Detector Wireless Indoor Siren Wireless Outdoor Siren Proximity Tags GSM/GPRS Communicator USER GUIDE © 2013 Visonic Ltd. All rights reserved. KP-160 PG2 Keypad English User Guide D-304456 for Your Security and Safety Needs: PowerG Technology for life Contact Visonic for further information: Email: info@visonic.