User`s guide
Chapter 4 - The Vision Menus 117 
To surface: This value is ignored when using the Vision Serial Controller 
or the VE-810 Engraver. The surface is set on the controller and in the VE-
810. 
Total depth: This is the total depth that you would like to engrave. This 
value is only needed when you are engraving without a nose cone. If you 
are using a nose cone, the value should be left at 0.000 because the depth is 
controlled by the nose cone. 
Z Lift: This value is ignored when using the Vision Serial Controller or the 
VE-810 engraver. The Z lift between characters is controlled from the 
Vision Serial Controller and from the front panel on the VE-810 
Passes: This is how many passes you would like to make to get to the total 
depth. 
Note: Vision will show you how deep every pass will be. 
Cleanup: This is how deep you would like the final pass to be. 
Pause before each pass: If this is selected, the engraving table will stop 
before it goes to a different depth pass. This would be used if you would 
like to change the cutter between passes. 
Pause before clean up pass: If this is selected, the engraving table will stop 
before it goes to the cleanup pass. This would be used if you would like to 
change the cutter before the cleanup pass. 
Clear: This will reset all of the parameters in the Pass Depths window to 
zero. 