User manual

50 VE810 Engraver Manual
(Figure 5.12) Motor Brush & Cap
Motor Brush
Motor Brush Cap
Motor Brush Cap
If the motor brush is over 1/8 of an inch, put the existing brush back into the motor and
replace the motor brush cap.
Next, put the three covers that you just removed back on.
Cleaning the Fan Filter
Weekly preventative maintenance should be performed to ensure reliable operation of
your VE-810. It is recommended that the input fan filter be removed weekly and cleaned
to ensure proper cooling of the electronics.
1. Unplug the power cable that goes into the back of the VE-810.
2. Remove the filter guard by using a small flat blade screwdriver to pop the guard open.
See figure 5.13.
3. Remove the filter and blow out the filter with low-pressure compressed air or rinse the
filter with water and dry before replacing.
4. Replace the filter and filter guard by snapping it back in place.