User manual

42 VE810 Engraver Manual
Without a vacuum chip removal system you should remove the cutter before attempting to
clean the nose cone. The nose cone retainer ring, the nose cone, and the micrometer
collar should all be removed and cleaned using a vacuum or blowing air. The three nose
cone components should be removed and cleaned at least every day, and as frequently
as necessary. Failure to clean the nose cone regularly will result in premature spindle
failure.
Cleaning the Vacuum Filter (only with the vacuum chip removal option)
On systems with a vacuum chip removal system, frequent cleaning of the vacuum filter is
necessary for proper performance. When engraving with the vacuum filter system, the
filter should be checked and cleaned several times a day, depending on the amount of
engraving done. If the vacuum does not appear to be functioning efficiently, clean the filter
more frequently as needed.
To clean the vacuum filter system, disconnect the vacuum hose from the canister. On the
lid of the canister, note the three wing nuts. Loosen these nuts enough to allow the
attached bolts to swing away from the lid, allowing removal of the lid. Do not loosen the
nuts enough to remove them completely. Remove the canister lid and inside you will find
two filters. Carefully remove the inner, paper filter. (The paper and cloth filters tend to
stick together.) Empty the paper filter, and shake it out completely, being careful not to
damage it, as the filters are reusable. After shaking out the paper filter remove and empty
the cloth filter in the same manner as the paper filter. Do not wash either filter. Place the
paper filter back inside the cloth filter, and place the cloth filter back inside the vacuum
canister.
Lubrication
Lubricating the X&Y-Axis Linear Rails
Apply 2-3 drops of light oil (such as 3-in-1 oil) on the rails and rub it in with your fingers.
Use the X jog button to move the spindle to the right and left to evenly distribute the oil.
Also, use the Y jog button to move the t-slot table front to back to evenly distribute the oil.
(See Figure 5.1)
Lubricating the X-Y-Z-Axis lead screws
A light lubrication of the X, Y and Z lead screws should be performed after every week of
usage. Use silicone lubricant only. To reach the Z-Axis lead screw, press the Z jog down
button to lower the spindle. This will expose the Z leadscrew so you can spray it with
lubricant.
DO NOT use any lubricant other than silicone, as it may become sticky and cause a
buildup that can cause mechanical failure.