7.10.1 Multi ROI setting parameters
(1) Multi ROI Index Max:Setting value = 0 ~ 4
Maximum 5 ROI settings are possible in a frame. Set Index 0 through 4 in Multi ROI Index
table as an application requires.
(2) Multi ROI Width
Multi ROI Width can be set individually for Multi ROI Index 0 to 4. The setting range and
Step number are the same as the normal ROI setting in which
“Video Send Mode” is set to ”Normal”. The restriction for setting Step and other factors are
the same as the normal ROI setting.
(3) Multi ROI Index Selector:
Index 0 to 4 can be selected. [Height], [Offset X], and [Offset Y] of the selected Multi ROI
Index are displayed and can be set.
(4) Multi ROI Offset X:
Offset X can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors are the same as the normal ROI setting.
The sum of Offset X and ROI Width must not be greater than Width Max.
(5) Multi ROI Height:
Height can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors are the same as the normal ROI setting.
(6) Multi ROI Offset Y:
Offset Y can be set for each ROI area of Multi ROI Index 0 to 4.
The restriction for setting Step and other factors is the same as the normal ROI setting.
The sum of Offset Y and ROI Height must not be greater than Height Max.