7.1.1.3 Continuous
In this mode, when the AcquisitionStart command is set, the image is continuously output at the
current frame rate. This is the default setting for the SP-5000M-GE2 and SP-5000C-GE2.
1) AcquisitionStart command is input
2) AcquisitionTriggerWait becomes effective
3) AcquisitionActive becomes TRUE
4) Images begin outputting continuously
5) AcquisitionStop command is sent
6) AcquisitionActive becomes FALSE”. At this moment, the output stops.
However, if AcqusitionStop command is initiated during image output period,
AcqusitionActive becomes FALSE (stop capturing) after image output is completed.
Associated commands Acqusition Start, Acqusition Stop