User manual

DVO Dust
263
© 2014 Digital Vision
UM-2014.1-07
MDC Scale
The
MDC
(Motion Detection Current) toggle button in the Processing section
determines whether to look at just the previous and next field/frame, or to look
at all of the previous, current, and next field/frame.
Only used if MDC (Motion Detection Current) control enabled in the
Processing section.
The higher the scale setting, the more filtering (less impact of the MDC
algorithm).
Range :
0 to 15
Default :
8
Edge
The Edge settings apply only if Edge protection has been enabled in
the Processing tab.
Offset
The edge offset acts like a threshold, determining how well-defined edges
have to be before the edge control has any effect. The smaller the offset value
the sooner the edge control will have an effect.
Range :
0 to 255
Default :
45
Scale
Edge scale sets the sensitivity of the edge control. The higher the setting the
more pronounced the effect of the edge control.
Range :
0 to 255
Default :
192