Installation guide

Introduction and Computer Requirements 5
© 2014 Vision Engraving & Routing Systems
2 General Electrical and Facility Requirements by Model
Machine Model
Requirements
Express, VE-810, 1612, 1624 Engraver, 2424, 2448,
MAX and MAX Pro
One 110 VAC 15 Amp, or One 220 VAC 10
Amp Single Phase
1624R, 2525 and 2550 Router - T-Slot Table
With High Frequency Router Head
With Engraving Head
With NSK High Frequency Spindle
One 110 VAC 15 Amp, or One 220 VAC 10
Amp Single Phase
AND One 220 VAC 30 Amp Single Phase
One 110 VAC 15 Amp, or One 220 VAC 10
Amp Single Phase
Two 110 VAC 15 Amp, or Two 220 VAC 10
Amp Single Phase
2550 Router with Vacuum Table
With High Frequency Router Head
With Engraving Head
With NSK High Frequency Spindle
One 110 VAC 15 Amp, or One 220 VAC 10
Amp Single Phase
AND One 220 VAC 30 Amp Single Phase
AND One 220 VAC 30 Amp 3 Phase
One 110 VAC 15 Amp, or One 220 VAC 10
Amp Single Phase
AND One 220 VAC 30 Amp 3 Phase
Two 110 VAC 15 Amp, or Two 220 VAC 10
Amp Single Phase
AND One 220 VAC 30 Amp 3 Phase
VR48 Router - T-Slot Table
One 220 VAC 50 Amp Single Phase
AND One 220 VAC 20 Amp Single Phase
VR48 Router - Vacuum Table
One 220 VAC 50 Amp Single Phase
AND One 220 VAC 20 Amp Single Phase
AND One 220 VAC 40 Amp 3 Phase
Optional Equipment
Vacuum Chip Removal System
One 110 VAC 15 Amp
Optional Equipment Requiring Compressed Air
Supply
UNIST Misting System
NSK High Frequency Spindle
Clean Dry Compressed Air Supply 60 - 90
PSI
Clean Dry Compressed Air Supply 1 SCFM
@ 40 PSI
NOTE: In addition to the above requirements a 110 VAC standard outlet will be required to run the