Installation Guide

Operation
1. Using adhesive tape to mount ZP3113 at 2 meters above surface. To enhance proper
operation, place ZP3113 on the location which can detect the room widely. The PIR
needs one minute to be stable after initial power on, please proceed motion detection after
that.
2. Walk in front of ZP3113, sensor will send Basic set On (0xFF) and Notification Report
please refer to status report as (Table 2) below.
3. If no movement detected in three minutes (default is 3 minutes - based on users
configuration setting, refer Parameter 5) will send Basic Set OFF (0x00) and Notification
Report refer to status report as (Table 2) below.
4. The ZP3113 equipped with tamper switch. If the tamper switch is triggered (or remove the
cover), the ZP3113 will send Notification Report refer to status report as (Table 2) below..
5. If the motion detection or tamper switch state change, LED will flash once
(default is LED Turn Off - based on users configuration setting, refer to Parameter 7) .
Notification V8
(Movement)
Notification V4
(Tamper Switch)
Alarm Type
-
-
Alarm Level
-
-
Notification
Type
0x07
0x07
Notification
Event
0x08(Motion detect)/
0x00(Motion detect
clear)
0x03(remove cover)/
0x00(cover closed)
Notification
Event
Parameter
0x08(Motion detect
clear)
0x03(cover closed)
(Table 2)
6. Support OTA Firmware update from controller. Please refer to your controller manual.
use COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5. To proceed the OTA process.
Once OTA function success, we recommend you exclusive the device & inclusive again
before use the device after OTA.
7. ZP3113-7 is a Security Enabled Z-Wave Plus
TM
product, A Security Enabled Z-Wave
controller must be used to fully utilize the product.
8. Factory Default Reset: Remove cover to trigged tamper switch, LED flash once & send
out Alarm Report. Press Program Switch 10 times within 10 seconds, ZP3113 will send
the Device Reset Locally Notification command and reset to the factory default.
(Remark: This is to be used only in the case of primary controller being inoperable or
otherwise unavailable.)
9. Support SECURITY S0, SECURITY S2 UNAUTHENTICATED & SECURITY S2
AUTHENTICATED.
10. Support SmartStart, please scan the QR Code from ZP3113 for SmartStart. QR code
and PIN is located on the device, also there is a Full DSK string on the enclosed DSK
card. Please keep DSK card carefully for future inclusion needed.
(P.S.: Z-Wave SmartStart aims to shift the tasks related to inclusion of an end device into
a Z-Wave network away from the end device itself, and towards the more user-friendly
interface of the gateway.)
11. The DSK label is on the backside of ZP3113US-7, Scan the DSK label to access the
SmartStart if gateway 's UI supports SmartStart
12. A Security Enabled Z-Wave Controller must be used to fully utilize the products.
13. All the reset commands depend on Z-Wave standard.
-8-