User manual
86
Note:
You may install all types of ISA interface I/O cards at the same time. However, they must have
different addresses.
RS232/RS485 interface:
(Allowing connections of 32 external I/O modules within a distance of 1.2
kilometers).
PT811 I/O device:
(8 ON/OFF inputs, and 8 digital output modules)
Address range: 0x01-0xFF. PT811’s address needs to be set before the delivery of goods is made.
Otherwise it will be necessary to seek required hardware and software support from the manufacturer.
Each PT-811’s address must be different from that of any other PT-811 on
the same COM port to avoid
any control errors.
Dome Camera
This system can simultaneously control up to 16 dome cameras. Since a control command is sent out by RS-
485 interface signals to all cameras, a camera will adjust its address in order to identify whether or not it can
receive the command. It is important that the camera’s address and setup location are remembered so that a
correct setting is made and any control error avoided. There are many brands of cameras and each brand has
different internal control commands, thus this system allows for more flexibility in users’ choices.
1.
Lilin PIH717X dome camera
The valid address range is 0x1-0x40 (in hexadecimal address). For the address setting, please refer to the
PIX 717 operating guide.
2.
DynaColor CA720 dome camera
The valid address range is 0x1-0xDF (in hexadecimal address). For the address setting, please refer to the
CA720 operating guide.
3.
Mikami PTC103A dome camera
The valid address range is 0x1-0x40(in hexadecimal address). For the address setting, please refer to the
PTC103A operating guide.
4.
Sensormatic dome camera (RS422 Interface)
The valid address range is 0x1-0x63(in hexadecimal address). For the address setting, please refer to the
Sensormatic operating guide.
The control code of each manufacturer is different to and incompatible with those of others’. Do not mix or
use different vendors’ devices on the same COM port. The address of each device on the same COM port
must be unique (different from each other). To avoid any control error, the address will need to be entered in a
hexadecimal format.
Adding an I/O device
Select and name the device, then click
Add
to add it to the list. If there is an address conflict or a mixed use of
differing brands of devices on the same COM port, the device will not be able to be added to the list. Below is
an example: