User manual

85
Chapter 7: I/O Device
The
CamSS
system can control an external I/O device. The I/O devices can generally be divided into three
categories as follows:
1.
Computer ISA Interface I/O card. This is used to detect the On/Off
state of the input point, or control the
ON/OFF state of the output point. It also can be used to control the traditional PTZ.
2.
RS232-to-RS485 interface I/O control device. It functions the same as the above.
3.
RS232-to-RS485 interface (high speed) dome camera control. Its operation is divided into two parts,
namely I/O Control and Camera PTZ control.
7.1 I/O Device Setup
The
I/O Device Setup
button
may be found on the
System
pull-down menu in the
System Operation Section
.
Click the button and enter into the
I/O Device Setup
screen:
Selecting the desired I/O device:
First, decide which I/O device type is needed. I/O devices are categorized by connection ports into two types,
i.e. ISA interface and RS232 (COM Port)-to-RS485 interfaces.
Devices supporting ISA Interface
CH-8I8O:
(8 voltage inputs and 8 relay outputs)
To set the address of the I/O devices, follow the operations guide regarding adjusting the DIP switches
on the I/O cards. The system default value is I/O port 0x300 (in hexadecimal address). The default
address is “OFF
OFF ON
ON ON ON ON
ON”.