Instruction manual

Specifications
44
5.2.4 I/O Module Cable
The I/O Module cable (Table 5-9) is used with the optional 1460 I/O Expansion Module,
1450 I/O Expansion Module and 1350 I/O Breakout Module. The I/O Module cable connects
the sensor directly to the applicable I/O module via the DB15 connector. When the 1460 I/O
Expansion Module, 1450 I/O Expansion Module or 1350 Breakout Module is used, all power
and communication lines used by the sensor are connected using the I/O Module cable.
NOTE:
Refer to the 1460 I/O Expansion Module, 1450 I/O Expansion Module or 1350 Breakout
Module Installation and Reference manual for more connection information.
Table 5-9: I/O Module Cable Pin-Out
P1 Pin# Signal Name P2 PIN#
1 Power, +24 VDC 1
2 Trigger + 2
3 Trigger - 3
4 High-Speed Out 0 4
5 High-Speed Out 1 5
6 RS-232 Receive (RxD) 6
7 RS-232 Transmit (TxD) 7
8 Ground 8