Instruction manual

Specifications
34
5.1.1 Standard Vision Sensor Specifications
Table 5-1: Standard Sensor Specifications
Specification
In-Sight
5000
In-Sight
5100
In-Sight
5401
In-Sight
5400C
In-Sight
5403
In-Sight
5400
Performance Class
Minimum Firmware Requirement In-Sight version 2.80.01 PR1
Memory Job/Program 32MB non-volatile flash memory; unlimited storage via remote network device.
Image
Processing
32MB 64MB
Image Sensor 1/4-inch CCD 1/3-inch CCD 1/1.8-inch
CCD
1/3-inch CCD
Optical
Properties
4.5mm
diagonal,
5.6 x 5.6µm
sq. pixels
6mm
diagonal,
7.4 x 7.4µm
sq. pixels
6mm
diagonal,
4.65 x 4.65µm
sq. pixels
6mm
diagonal,
7.4 x 7.4µm
sq. pixels
8.923mm
diagonal,
4.4 x 4.4µm
sq. pixels
6mm
diagonal,
7.4 x 7.4µm
sq. pixels
Resolution
(pixels)
640 x 480 1024 x 768 640 x 480 1600 x 1200 640 x 480
Electronic
Shutter Speed
32µs to
1000ms
16µs to
1000ms
32µs to
1000ms
16µs to
1000ms
27µs to
1000ms
16µs to
1000ms
Acquisition Rapid reset, progressive scan, full-frame integration.
256 gray levels (8 bits/pixel) 24 bit color 256 gray levels (8 bits/pixel)
Gain/Offset controlled by software.
25 full frames
per second at
8ms exposure.
40 full frames
per second at
8ms exposure.
17 full frames
per second at
8ms exposure.
40 full frames
per second at
8ms exposure.
13 full frames
per second at
8ms exposure.
40 full frames
per second at
8ms exposure.
Lens Type C-mount
Image
Repeatability
1
±0.005in (.0127mm), (both x and y) from lens C-mount axis to center of imager.
I/O Trigger 1 opto-isolated, acquisition trigger input.
Remote software commands via Ethernet and RS-232.
Discrete Inputs 8 inputs available, using the optional 1450/1460 I/O Expansion Module. Unlimited inputs when
using an Ethernet I/O system.
Discrete
Outputs
2 built-in, high-speed outputs.
8 additional outputs available, using the optional 1450/1460 I/O Expansion Module. Unlimited
outputs when using an Ethernet I/O system.
Status LEDs Power, Network Status, Network Traffic, 2 user configurable.
Communications Network 1 Ethernet port, 10/100 BaseT, TCP/IP protocol. Supports DHCP (factory default) or static IP
address.
Serial RS-232C (4800 to 115,200 baud rates; 1200 to 115,200 baud rates when connected to a 1450/
1460 I/O Expansion Module).
Power 24VDC ±10%, 350mA maximum. 24VDC ±10%,
500mA
maximum.
24VDC ±10%,
350mA
maximum.