Instruction manual

Installing In-Sight
®
5000 Series Vision Sensors
21
5. Plug the M12 connector of the I/O Module Cable into the sensor’s 24VDC connector.
6. Plug wire leads from a 24VDC supply for the +24V power and ground into the 2 pin terminal
plug labeled “Power Input” on the Expansion Module.
7. Restore power to the 24VDC supply. The green power LED on the sensor and the +24V LED
on the Expansion Module indicate that the sensor is receiving power.
NOTE:
The I/O Module’s standard components do not include an I/O module cable; it must be
purchased separately.
!
CAUTION: Never connect the 1450 I/O Expansion Module to a power source other than
24VDC. Any other voltage creates a risk of fire or shock and can damage the
hardware. Do not connect the 24VDC source to any terminals other than the
2 pin 24VDC power connector.