Instruction manual
Installing In-Sight
®
5000 Series Vision Sensors
17
3.3 Connecting the Model 1460 I/O Expansion Module
Like the 1350 Breakout Module and the Model 1450 I/O Expansion Module, the optional
Model 1460 I/O Expansion Module (P/N 800-5815-1) provides convenient access to the
sensor’s power, serial communications and discrete I/O lines. In addition to the two discrete
outputs, acquisition trigger and serial transmit/receive that are standard on the sensor, the
I/O Expansion module provides the following:
• 8 discrete outputs
• 8 discrete inputs
• RS-232 hardware handshaking
• Light Control
• Plug-in connections for I/O opto-isolator modules
To Connect a 1460 I/O Expansion Module to the In-Sight Sensor:
1. Verify the 24VDC power supply being used is switched off.
2. Connect the power and ground wires from remote I/O devices to terminals on the
1460 I/O Expansion Module (Figure 3-6).
Figure 3-6: Connecting I/O Wires
a. Use a flat-head screwdriver to loosen the screw terminals.
b. Insert wire leads from remote I/O devices into the appropriate positions on the terminal
block.
c. Tighten the screw terminals with the screwdriver to secure the wire leads in the terminal
block.
NOTE:
The 1460 I/O Expansion Module outputs labeled HSOUT 0 and HSOUT 1 correspond to the
sensor’s built-in outputs. These signals pass through the micro-controller on the 1460 I/O
Expansion Module without processing. In contrast, the general-purpose outputs labeled
OUT 0 through OUT 7 are lower speed because the micro-controller processes these signals
before they are transmitted to remote devices.