● Setting
- Select a bank of the user setting
Set the following value to “UserSetSelector” register. The setting value is Enumeration type.
Select the bank of user setting for “UserSetLoad” and “UserSetSave”.
setting value Description Save Load
Default (*) Memory bank to read initial factory setting data.
× ○
UserSet1 Memory bank 1 for user setting. ○ ○
UserSet2 Memory bank 2 for user setting. ○ ○
UserSet3 Memory bank 3 for user setting. ○ ○
SafeMode Memory bank for maintenance. × ○
* initial factory setting
“Default” and “SafeMode” banks are only able to load data. If you want to restore a camera setting to the
initial factory setting, please load “Default” bank.
- Load/Save a user setting
When execute “UserSetLoad”, the camera loads the user setting of bank that is selected in
“UserSetSelector” register and applies them.
When execute “UserSetSave”, the camera saves a user setting that was applied to the bank that is
selected in “UserSetSelector” register.
- Load the user setting at the time of start-up
Set the following value to “UserSetDefaultSelector” register. The setting value is Enumeration type.
When select “UserSetDefaultSelector” register and save it, the camera loads the user setting of bank that
is selected in “UserSetDefaultSelector” register and applies them at the time of next start-up.
● Note
Changing “UserSetLoad” register value is invalid during image stream data output.