Instruction manual

57 / 69
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/index.htm
D4211908A
LUTControl
This section describes LUTControl category for the Bees GigE series.
This function allows you to apply the
arbitrary
LUT(input: 10bit, output: 10bit) to the output images.
Registers
Register Visibility Access
Description
LUTSelector Expert R Returns the luminance component of LUT process.
LUTEnable Expert R/W Sets the activation of LUT process.
LUTIndex Guru R/W Sets the input level of LUT process.
LUTValue Guru R/W Sets the output level of LUT process.
Setting
- Set the activation of LUT
Set the following value to “LUTEnable” register. The setting value is Boolean type.
setting value function
FALSE (*) Inactivation
TRUE Activation
* initial factory setting
- Set the input/output value of LUT
Set the following value to “LUTIndex”, “LUTValue” registers. These setting values are Integer type.
“LUTIndex” register value is input level of LUT process, and “LUTValue” register value is output level of
LUT process.
LUTIndex / LUTValue setting value
Minimum (*) 0
Maximum 1023
* initial factory setting
Note