TimerControl
This section describes TimerControl category for the Bees GigE series.
This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting.
This signal can be used as strobe control signal.
Fig. Timer0Active
Registers
Register Visibility
Access Description
TimerSelector Expert R Returns the name of the timer that selected.
TimerDuration Expert R/W Sets the width of Timer0Active signal.
TimerDelay Expert R/W Sets the delay of Timer0Active signal.
TimerTriggerSource Expert R Returns the timing that is the basic of the timer
Setting
- Set the width of Timer0Active pulse
Set the following value to “TimerDuration” register. Setting value is Float type.
TimerDuration Pulse width
Minimun (*) 0.00[µs]
Maximum 4095.00[µs]
* initial factory setting