Instruction manual
40 / 69
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/index.htm
D4211908A
AcquisitionControl
Make a setting of image stream and control image stream output.
Camera starts image stream output by receiving AcquisitionStrat command. And there are some registers
that require camera to stop image stream output to change values.
Acquisition frame rate is variable. Maximum acquisition frame rate depends on camera operation mode
(scalable, binning, draft, link speed, etc.)
● Registers
Register Visibility Access
Description
AcquisitionMode Beginner R Returns acquisition mode.
AcquisitionStart Beginner W Executes the image stream output start.
AcquisitionStop Beginner W Executes the image stream output stop.
AcquisitionAbort Beginner W Executes the image stream output abort.
AcquisitionFrameRate Beginner R/W Sets frame rate of image stream.
● Setting
- Start image stream output
The camera starts image stream output by executing “AcquisitionStart” register command.
- Stop image stream output
The camera stops image stream output by executing “AcquisitionStop” register command.
The camera aborts image stream output by executing “AcquisitionAbort” register command.
- Sets frame rate
Set the following value to “AcquisitionFrameRate” register. Setting value is Float type.
The range of register setting depends on camera model, and camera operation mode.
setting value FrameRate
Minimum 0.0625[Hz]
Maximum (*) Depend on register setting of "Height" and "Binning" or link speed of interface.
* initial factory setting