Instruction manual

39 / 69
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/index.htm
D4211908A
Registers
Register Visibility Access
Description
TestImageSelector Beginner R/W Selects a test pattern.
Setting
- Select a test pattern output
Set the following value to “TestImageSelector” register. Setting value is Enumeration type.
The camera generates a test pattern.
setting value function
Off (*) Test pattern disable(Normal data output)
Black All pixel = 0 LSB
White All pixel = 255 @Mono8
BrightGrey All pixel = 170 @Mono8
DarkGrey All pixel = 85 @Mono8
GreyHorizontalRamp Horizontal Ramp
* initial factory setting