Instruction manual

30 / 69
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/index.htm
D4211908A
Operating Ambient Conditions
Ambient conditions
- Operating Assurance
Temperature: 0°C ~ 40°C, Camera housing temperature: less than 50°C
Humidity: 10% ~ 90% (no condensation)
- Storage Assurance
Temperature: -20°C ~ 60°C
Humidity: 90% or less (no condensation)
EMC Conditions
- EMI (Electro-Magnetic Interference): EN61000-6-4
FCC Part 15 Subpart B Class A
- EMS (Electro-Magnetic Susceptibility): EN61000-6-2
Notes on Heat Radiation:
The temperature of camera housing must be kept less than 50 °C.
Please provide sufficient heat radiation depending on your installation.
Notes on Conformity of the EMC:
The adaptability of the safety standard of this camera is assured in the condition of combination with the following parts:
<<
PoE operation>>
- PoE Switch GS108P-100AJS (NETGEAR Inc.)
- LAN Cable C5e(S-HFR)(K)-* (Oki Electric Cable Co., Ltd.)
<<
DC operation>>
- DC Cable CPCBG-03
- LAN Cable C5e(S-HFR)(K)-* (Oki Electric Cable Co., Ltd.)
Please confirm the EMC adaptability when it combines with parts other than them.